OREMA UNH high-rate battery: product specifications, UNH12-520W
Original title OREMA UNH high-rate battery: product specifications: UNH / UNH12-520W
OREMA Power
OREMA UNH12-520W: a 138 Ah, 12 V AGM high-rate VRLA battery with a 15-minute discharge capacity of 520 W, 44 kg weight and 10-12-year design life, for UPS and data-centre use.
On this page
Overview
The page presents the UNH12-520W from OREMA's UNH series. The series is 12 V high-rate VRLA batteries designed for UPS systems, data centres and electrical systems, and is based on AGM technology. The manufacturer states that a special corrosion-resistant alloy and thinner plates give a larger plate surface area than ordinary batteries, which allows short, high power pulses. The model is written as 138 Ah, 12 V, with a 15-minute discharge capacity of 520 W at 25 °C.
Physical data: weight 44 kg, length 341 mm, width 173 mm. Terminal F11 veya F12. Design life is 10-12 years at 25 °C and warranty is 24 months. Listed certificates are ISO 9001, ISO 14001, ISO 45001, UL, CE and TLC. The carton holds 1 battery. Origin is China; the brand is offered as OREMA or OEM label, with a minimum order of 10 pieces.
The feature list includes a pure lead-calcium grid design, tank-formed plates, plate groups anchored against vibration, low-pressure flame-arresting safety valves, 99 percent internal gas recombination and use in any orientation. The battery is classed as non-spillable and complies with IATA/ICAO provision A67; self-discharge is low and shelf life is six months at 20 °C.
The FAQ explains that a high-rate battery is built for short, high power pulses and that cycle life depends on depth of discharge; keeping discharge near 50 percent gives more useful cycles. The page is a product introduction without a discharge table or full datasheet, so a runtime calculation needs the manufacturer's discharge table separately. The page also states that this model delivers up to 50 percent more energy per kilogram than regular NP types at a 10-minute discharge.
Key points
- Model UNH12-520W; 12 V, 138 Ah AGM VRLA battery.
- 15-minute discharge capacity 520 W at 25 °C.
- Weight 44 kg; length 341 mm, width 173 mm.
- Terminal F11 veya F12; 1 battery per carton.
- Design life 10-12 years at 25 °C; warranty 24 months.
- Certificates: ISO 9001, ISO 14001, ISO 45001, UL, CE, TLC.
- 99 percent internal gas recombination, any-orientation use, non-spillable class (IATA/ICAO A67).
- Minimum order 10 pieces; payment L/C, T/T, D/P, D/A; delivery FOB, CFR, CIF, EXW.
Using it in design
- Compare the 15-minute W rating with the UPS string's power and runtime requirement; request the discharge table from the manufacturer for longer durations.
- Include the string weight in rack and floor-loading calculations, multiplying this weight by the number of batteries.
- Assess design life against ambient temperature; the value applies at 25 °C and falls at higher temperature.
- Match the terminal type (F11 or F12) with the UPS battery connection kit.
Who should read it
Electrical designers selecting UPS battery strings and teams preparing battery comparison data.
Publication details
- Authors
- OREMA Power
- Publisher
- OREMA Power
- Year
- Year not stated
- Document language
- Unverified
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
OREMA Power OREMA UNH high-rate battery: product specifications: UNH / UNH12-520W. OREMA Power. https://www.oremapower.com/high-rate-battery/62828274.html
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.