Sunstone Power SPT (Spirit) Series AGM Battery Datasheets
Original title Sunstone Power SPT Spirit AGM JPG datasheets
Sunstone Power
Sunstone Power's downloads page offers 13 datasheets for the SPT Spirit series of 6 V and 12 V AGM monoblocs, from SPT6-4.5 to SPT12-20, with capacity stated as C20 at 25 C and 1.80 V per cell.
On this page
Overview
The Sunstone Power Industry (Shenzhen) downloads page lists one datasheet per model of the SPT (Spirit) AGM series: SPT6-4.5, SPT6-5, SPT6-7, SPT12-4.5, SPT12-5, SPT12-7, SPT12-7.2, SPT12-9, SPT12-12, SPT12-14, SPT12-17, SPT12-18 and SPT12-20. The datasheets are published as images (JPG) of about 1 MB each.
This source supports twelve new monobloc entries for UPS applications. Capacity values are read as C20 (20-hour discharge) at 25 C and 1.80 V per cell, and height including terminal is read from the image. The published mass is approximate; mass that could not be read in the preview is left blank.
Key points
- 13 models are listed: SPT6-4.5, 6-5, 6-7 and SPT12-4.5, 12-5, 12-7, 12-7.2, 12-9, 12-12, 12-14, 12-17, 12-18, 12-20.
- Capacity is given as C20 at 25 C and 1.80 V per cell.
- Height is read as the value including terminal; mass is approximate.
- The series uses VRLA AGM technology; datasheets are published as one JPG per model.
Using it in design
- When comparing capacity, do not mix the C20 value with the capacity at the shorter discharge time that UPS runtime calculations need; use the relevant discharge table.
- Use height including terminal for cabinet layout.
- Because mass is approximate, confirm a net value with the manufacturer for floor loading.
- In the spare-battery stock list, define 6 V and 12 V models as separate items.
Who should read it
Electrical designers and maintenance teams cataloguing UPS battery blocks and selecting replacements.
Publication details
- Authors
- Sunstone Power
- Publisher
- Sunstone Power
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Sunstone Power Sunstone Power SPT Spirit AGM JPG datasheets. Sunstone Power. https://www.sunstonepower.com/downloads/170.html