CHAYO / TONGOU TOATS-2P automatic transfer switch

Original title CHAYO / TONGOU TOATS2P automatic transfer switch

Changyou Technology

A CHAYO (TONGOU) product page from Changyou Technology for the DIN-rail TOATS-2P automatic transfer switch: PC class, 2 poles, 63 A rated current, AC 110/220 V, 50/60 Hz and a transfer time below 50 ms.

On this page

Overview

The page presents the TOATS series DIN-rail automatic transfer switch (ATS) from Changyou Technology, based in Wenzhou in China's Zhejiang province. The TONGOU address offers the product under the CHAYO brand; a notice on the page states that the EU trademarks "tongou" and "Chayo" are both owned by Changyou Technology (Zhejiang) Co., Ltd. The product is positioned for solar PV systems and small dual-supply AC circuits and is listed in the ATS category. The warranty is 1 year.

The product description defines the TOATS as a PC-class change-over switch for infrequent operation. In its two-position design, input A is the normal source and input B the standby source. When the main source fails, the switch transfers to the standby source automatically. The series suits AC systems at 50 to 60 Hz with rated currents from 6 A to 63 A. Manual and automatic operation are combined in one body, and the housing material is described as resistant to heat, cold and wear.

The technical data table is short: model TOATS, manufacturer Chayo, 2 poles, rated current 63 A, insulation voltage AC 690 V, rated voltage AC 110/220 V, rated frequency 50/60 Hz and CE marking. Transfer time is stated differently in two places: the product summary gives less than 50 ms, while the general section gives 0.02 seconds. Both values sit at or above the typical hold-up time of an IT power supply.

The page contains no short-circuit withstand current, utilisation category, mechanical or electrical endurance, retransfer delay, voltage sensing thresholds or declaration of conformity to IEC 60947-6-1. Other current ratings between 6 A and 63 A are not listed as separate models. The same page links to the 4-pole TOATS-4P and to the 2, 3 and 4-pole dual power switches of the TOWTS series. This level of data is enough to identify the product for small, non-critical circuits.

Key points

  1. Model TOATS-2P: DIN-rail, PC-class automatic transfer switch, 2 poles.
  2. Rated current 63 A; the series suits the 6...63 A range.
  3. Rated voltage AC 110/220 V, rated frequency 50/60 Hz, insulation voltage AC 690 V.
  4. Transfer time is given as under 50 ms in the product summary and 0.02 s in the general section.
  5. Two-position design: A normal source, B standby source; manual and automatic operation combined.
  6. CE marked; 1-year warranty.
  7. The CHAYO and TONGOU trademarks are owned by Changyou Technology (Zhejiang) Co., Ltd.

Using it in design

  • Do not use this switch on circuits that feed IT load directly: a 20 to 50 ms transfer can exceed server power-supply hold-up time; for IT loads, place it upstream of a UPS or use a static transfer switch.
  • Consider it for single-phase circuits up to 63 A that tolerate a short break, such as lighting, monitoring panels or auxiliary services.
  • Calculate the prospective short-circuit current of the circuit and obtain the switch's short-circuit withstand rating from the manufacturer in writing; the page does not give it.
  • A PC-class switch provides no overcurrent protection; fit a suitable breaker or fuse on both source sides.
  • Account in the earthing system design (TN-S, TT) for the fact that the 2-pole device switches phase and neutral together.

Who should read it

Electrical designers and panel builders selecting a transfer switch for small dual-supply AC circuits.

Document contents

  1. Description
  2. General
  3. Technical Data
  4. Similar Products

Publication details

Authors
Changyou Technology
Publisher
Changyou Technology
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Changyou Technology CHAYO / TONGOU TOATS2P automatic transfer switch. Changyou Technology. https://www.tongou.com/product/din-rail-ats-2p-automatic-transfer-switch/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.