Technical guideFree to readYear not stated

Elettro NTX Nexus single-phase UPS product page

Elettro Services & Equipment

A product page from Italian manufacturer Elettro Services & Equipment presenting the NTX Nexus single-phase, online, double-conversion UPS with transformer: six ratings of 3, 4, 5.5, 7, 10 and 14 kVA, a manual maintenance bypass and emergency power off (EPO) contacts.

On this page

Overview

The page describes the NTX Nexus series, part of the standard UPS range of Elettro Services & Equipment, which manufactures in Trezzano sul Naviglio near Milan. The series is a single-phase in, single-phase out UPS designed for low-power industrial applications. The topology is online double conversion, the output is a sine wave and the unit includes a transformer. A manual bypass to feed the load during maintenance and contacts for emergency power off (EPO) are standard. The ratings are 3, 4, 5.5, 7, 10 and 14 kVA.

The manufacturer highlights two design choices. The first is layout: components are spread over several assemblies instead of one large circuit board, so a single component is replaced after a fault instead of a whole power block. The second is long autonomy: the battery chargers are sized to charge the battery correctly and in time, and the inverter can supply the load in battery mode for very long periods. The page contrasts this with standard single-phase products that risk overheating when the battery discharge lasts more than 30 minutes.

The page is an introduction; it holds no kW values, power factor, efficiency, input voltage window, dimension or weight table. Only the kVA ratings are given exactly. It also states that NTX models are available with three-phase input and single-phase output (3/1) and in versions for emergency lighting applications. Communication, self-diagnosis and high performance are named as general features. The series is positioned for process industry and for facilities that need long backup times more than for data centres.

Key points

  1. Ratings: 3 kVA, 4 kVA, 5.5 kVA, 7 kVA, 10 kVA and 14 kVA (six models).
  2. Single-phase input and output; 3/1 (three-phase in, single-phase out) versions are also offered.
  3. Topology: online, double conversion, sine-wave output, with transformer.
  4. Standard equipment: manual maintenance bypass and EPO contacts.
  5. Components are spread over several assemblies; a single component is replaced after a fault.
  6. The inverter is designed to run continuously through long battery discharges beyond 30 minutes.
  7. Separate versions exist for emergency lighting applications.

Using it in design

  • For auxiliary loads that need more than 30 minutes of autonomy (control, security, process), make the inverter's continuous operation in long discharge a selection criterion and obtain written confirmation from the manufacturer.
  • The page gives kVA only, so request the model datasheet for kW capacity, power factor and efficiency, and do not finalise sizing before those values arrive.
  • Treat the effect of the transformer-based build on weight and heat loss as a separate item in the layout and cooling calculation.
  • For single-phase loads fed from three-phase distribution, compare the 3/1 version as an option to reduce phase imbalance.
  • Wire the EPO contacts into the building emergency shutdown circuit and write the manual bypass operating sequence into the maintenance procedure.

Who should read it

Electrical designers selecting a 3-14 kVA single-phase UPS for industrial plants and auxiliary systems, and engineers planning long-autonomy backup.

Document contents

  1. NTX Nexus UPS
  2. Layout and maintenance approach
  3. Battery charging and long autonomy
  4. Power range
  5. 3/1 and emergency lighting versions

Publication details

Authors
Elettro Services & Equipment
Publisher
Elettro Services & Equipment
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Elettro Services & Equipment Elettro NTX Nexus single-phase UPS product page. Elettro Services & Equipment. https://www.elettroservices.com/en/products/nexus-ups-single-phase/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.