PHASAK PH 9380 official product page (Titan 10 kVA Rack, 3P/3P and 3P/1P)
Original title PHASAK PH 9380 official product page
PHASAK
The PHASAK PH 9380 is a 10 kVA / 10 kW, power factor 1.0, DSP-controlled 19-inch rack double-conversion online UPS: 3P/3P or 3P/1P, parallelable up to 4 units and 27 kg.
On this page
Overview
The page presents the PH 9380 from the PHASAK Titan Rack family. The unit is a 10 kVA / 10 kW true double-conversion online UPS with power factor 1.0 and DSP control, giving stable voltage and frequency against grid variations, spikes and micro-outages. The format is 19-inch rack, and an auto-rotating touch LCD simplifies installation and operation. Topology is 3P/3P or 3P/1P depending on configuration.
Main features: parallel operation of up to 4 units (for more power or N+1 redundancy), autonomy extendable with PH 9389 external battery banks, dual AC inputs for availability, ECO mode for efficiency, EPO (emergency power off) and cold start, generator compatibility, and remote management through USB HID, RS232 and optional SNMP.
Recommended applications are data centres, IT racks, network electronics, control rooms, broadcasting, communications, industry, automation and laboratories. The page stresses that power factor 1.0 gives more usable kW per installed kVA, that advanced management includes event logging, alarms and controlled shutdowns, and that power or autonomy can grow without re-scaling the infrastructure. The additional information gives dimensions of 133 x 438 x 680 mm (H x W x D), weight 27 kg, gross weight 33 kg and packaging of 870 x 580 x 250 mm. Runtime values are not given on the page.
Key points
- Model PH 9380; 10 kVA / 10 kW; power factor 1.0; DSP-controlled true double conversion.
- Topology 3P/3P or 3P/1P (depending on configuration).
- Parallel operation of up to 4 units: more power or N+1.
- Autonomy extendable with PH 9389 external battery banks.
- Dual AC inputs, ECO mode, EPO, cold start and generator compatibility.
- Remote management through USB HID, RS232 and optional SNMP.
- 19-inch rack; 133 x 438 x 680 mm (H x W x D); 27 kg (gross 33 kg).
- EAN 5605922006588.
Using it in design
- Size the system with margin and plan for three-phase distribution or conversion to single phase as required.
- Plan adequate bypass and grounding and verify line gauge.
- Document the parallel configuration and PH 9389 autonomy solution in the technical report.
- Compare the 27 kg weight with rack load capacity and the installation manual.
Who should read it
Data-centre and control-room designers selecting rack-mounted three-phase UPS units.
Publication details
- Authors
- PHASAK
- Publisher
- PHASAK
- Year
- Year not stated
- Document language
- Unverified
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
PHASAK PHASAK PH 9380 official product page. PHASAK. https://phasak.com/en/catalogo/ups-phasak-titan-10-kva-10-kw-3p-3p-%C2%B7-3p-1p-ph-9380-online-double-conversion
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.