Technical guideFree to readYear not stated

PHASAK PH 9283 official product page (Online UPS 3P/3P 30000 VA)

Original title PHASAK PH 9283 official product page

PHASAK

The PHASAK PH 9283 is a 30 kVA three-phase double-conversion online UPS with pure sine output, zero transfer time, autonomy extendable with external battery banks, 815 x 300 x 1000 mm and 225 kg.

On this page

Overview

The page presents the PH 9283 from the PHASAK Tempus 3P/3P family. The unit is a 30 kVA true double-conversion online UPS that provides service continuity against grid variations, spikes, micro-outages and prolonged failures. It offers pure sine output and precise voltage and frequency regulation, and supports external battery banks to extend autonomy according to load and usage scenario.

The manufacturer lists the key benefits as true double conversion with full isolation between input and output, zero transfer time and intelligent battery management, regulated voltage and frequency to protect sensitive electronics, and local supervision with remote monitoring through an optional SNMP card. The SNMP module provides remote monitoring, alarms and controlled shutdowns. Recommended applications are data centres, technical rooms, corporate networks, industrial processes with high continuity requirements, and healthcare, education and administration with critical (non-life-support) loads.

The additional information section gives the type as online double conversion, the format as tower and the waveform as pure sine. Dimensions are 815 x 300 x 1000 mm (H x W x D) and weight and gross weight are 225 kg. The page does not detail battery bank model codes or runtime values; it refers to the manufacturer's PDF catalogue for compatible accessories and cards.

Key points

  1. Model PH 9283; 30 kVA; three-phase input and output (3P/3P) double-conversion online UPS.
  2. Pure sine output; precise voltage and frequency regulation; zero transfer time.
  3. Autonomy can be extended with external battery banks.
  4. Local supervision; optional SNMP module for remote monitoring, alarms and controlled shutdowns.
  5. Tower format; 815 x 300 x 1000 mm (H x W x D).
  6. Weight 225 kg (gross weight 225 kg); packaging 1000 x 815 x 300 mm.
  7. EAN 5605922021734; ISO 9001 certified manufacturer.

Using it in design

  • Plan floor loading and placement for the 225 kg tower with 300 mm width.
  • Select the external battery bank for the required runtime from the manufacturer's catalogue; the page gives no runtime value.
  • For technical rooms and data centres, include the SNMP card in the order scope and connect it to monitoring.
  • Do not connect life-support systems to this UPS; the page defines critical loads as non-life-support.

Who should read it

Data-centre and technical-room designers selecting mid-range three-phase UPS units.

Publication details

Authors
PHASAK
Publisher
PHASAK
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

PHASAK PHASAK PH 9283 official product page. PHASAK. https://phasak.com/en/catalogo/phasak-online-ups-3p-3p-30000-va-ph-9283

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.