Gama Sonic UPS2KXL official product technical specifications

Gama Sonic Argentina

A product page from Gama Sonic Argentina describing the UPS2KXL single-phase online double-conversion UPS: 2 kVA / 1.8 kW at 220 VAC with a 48 V external battery (with the optional BT04048C cabinet), 0 ms transfer from mains to battery and an input power factor of 0.99.

On this page

Overview

The page presents, in Spanish, the UPS2KXL model in the online UPS family of Gama Sonic Argentina, a maker of emergency lighting and power protection products. The unit is a double-conversion online UPS with full digital control; it protects against outages, spikes, voltage fluctuations and electrical noise and delivers clean, continuous power on unstable grids. Capacity is 2 kVA / 1.8 kW, which gives an output power factor of 0.9. The page holds a specification table, a feature list and download links for the datasheet, manual and certification.

According to the specification table, rated voltage is 220 VAC, the input voltage range is 176-264 VAC and the frequency range is 40-70 Hz with automatic detection. The feature list also states a wide input range of 110-300 VAC and an input power factor of 0.99 with PFC; output voltage is selectable at 208/220/230/240 VAC. In battery mode, output voltage regulation is ±1%, frequency is 50 or 60 Hz ±1 Hz and the waveform is a pure sine wave. Transfer from AC mode to battery mode takes 0 ms and from inverter to bypass typically 4 ms.

The battery row reads 48 VDC 9 Ah and charging time is 4 hours. This model uses an external battery: the battery sits in the separately sold BT04048C 48 V external battery cabinet, which is delivered without batteries. An accessory with a maintenance switch is also offered as compatible with UPS2KXL. LED indicators show line, battery, ECO and bypass modes and faults; the LCD shows input and output voltage and frequency, load percentage, battery voltage, internal temperature and remaining backup time.

The chassis measures 460 x 191 x 337 mm and weighs 19.5 kg, with 4 outlets and RS232 and USB ports. The operating environment is 0-40 °C at 20-90% non-condensing relative humidity and noise is below 55 dB. Emergency power off (EPO), an ECO mode for energy saving, generator compatibility, cold start and intelligent fan speed control are standard. Protection functions cover short circuit, overload, overtemperature, battery overcharge and overdischarge, low output voltage and a fan failure alarm. The page gives no efficiency, overload times or runtime table.

Key points

  1. Model: UPS2KXL, 2 kVA / 1.8 kW, online double conversion, single-phase 220 VAC.
  2. Input voltage range 176-264 VAC in the table; wide range of 110-300 VAC in the feature list; frequency 40-70 Hz.
  3. Input power factor 0.99 with PFC; output voltage selectable at 208/220/230/240 VAC.
  4. Transfer time: 0 ms from mains to battery, typically 4 ms from inverter to bypass.
  5. Output regulation in battery mode ±1%, frequency 50 or 60 Hz ±1 Hz, pure sine wave.
  6. Battery: 48 VDC 9 Ah, external (BT04048C cabinet optional); charging time 4 hours.
  7. Dimensions 460 x 191 x 337 mm, weight 19.5 kg, 4 outlets, RS232 and USB.
  8. Environment: 0-40 °C, 20-90% relative humidity non-condensing; noise below 55 dB.
  9. EPO, ECO mode, generator compatibility and cold start are standard.

Using it in design

  • Compare the load against the kW value: UPS2KXL carries at most 1.8 kW, which is about 8.2 A of output current at 220 V.
  • Compare the typical 4 ms inverter-to-bypass transfer with the hold-up time of the load power supplies; this transfer comes into play on overload and fault.
  • Add the external 48 V battery set and the BT04048C cabinet to the layout as separate items; choose battery capacity for the required autonomy and provide ventilation and maintenance access for the cabinet.
  • For operation at full load, work from the 176-264 VAC range in the table, and confirm from the datasheet the load level at which the wide 110-300 VAC range applies.
  • Wire the EPO input into the room's emergency shutdown circuit and configure shutdown software over RS232 or USB for remote monitoring.

Who should read it

IT infrastructure engineers selecting a 1-3 kVA online UPS for network cabinets, small IT rooms and auxiliary systems, and teams procuring in the Argentine market.

Document contents

  1. Product introduction
  2. Especificaciones técnicas
  3. Características
  4. Archivos descargables: certification, datasheet, manual
  5. Productos relacionados

Publication details

Authors
Gama Sonic Argentina
Publisher
Gama Sonic Argentina
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Gama Sonic Argentina Gama Sonic UPS2KXL official product technical specifications. Gama Sonic Argentina. https://gamasonic.com.ar/producto/ups2kxl/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.