MAXGE MCCB and ATS catalogue, 202509 V5
MAXGE
MAXGE's catalogue of moulded-case circuit breakers (MCCB) and automatic transfer switches (ATS), giving current options and control-unit scope for the ATS1, ATS3 and ATS4-GA series.
On this page
Overview
The catalogue (September 2025, V5) covers MCCB products and four ATS series; ATS1, ATS3 and ATS4-GA are covered here. The series switch automatically between two sources, and each rests on a different current range and breaker class: ATS1 is a CB-class unit built from miniature breakers, ATS3 a CB-class unit built from two moulded-case breakers, and ATS4-GA a PC-class switch driven by an electromagnetic coil.
The ATS1 series (63M model) consists of two 3P or 4P miniature circuit breakers, a mechanical chain mechanism and a controller. It is defined by 400 V AC, 50/60 Hz, 220 V control voltage, currents of 6, 10, 16, 20, 25, 32, 40, 50 and 63 A, a transfer time of 1.5 to 3 s and a mechanical life of 10000 operations. In the model code, X means economical, Y fire type and M mini type.
The ATS3 series is 3P and 4P, three-position, motor-driven, with an integral or split controller. Current options are 16, 32, 63 A for ATS3-63; 80, 100 A for ATS3-100; 125, 160, 200, 225 A for ATS3-225; 315, 400 A for ATS3-400; 500, 630 A for ATS3-630; 800 A for ATS3-800; and 1000, 1250 A for ATS3-1250. In the split type the controller is mounted in the panel and connected with about 2 m of cable.
The ATS4-GA series offers discrete current options from 16 A to 3200 A (frames of 100, 250, 630, 1600 and 3200 A). The integral GA type has three positions and includes over-voltage, under-voltage and phase-loss detection, plus a generator start/stop signal output with a 3 s delay when the main supply fails. The technical table gives utilisation categories AC-33B/AC-33iB, 8 kV impulse voltage, 400 V working voltage, short-circuit withstand values and transfer times.
Key points
- Discrete current selections are given for ATS1-63M, ATS3 and ATS4-GA: ATS1 6-63 A, ATS3 16-1250 A, ATS4-GA 16-3200 A.
- ATS1: 400 V AC, 50/60 Hz, 220 V control, transfer time 1.5-3 s, mechanical life 10000 operations.
- ATS3: 3P/4P, three positions, motor-driven, integral or split controller (about 2 m cable in the split type).
- ATS4-GA: frames 100, 250, 630, 1600, 3200 A; AC-33B for the 100 A frame, AC-33iB for larger frames.
- ATS4-GA rated limited short-circuit current 8 kA, 26 kA and 67 kA (by frame); transfer I-II or II-I 0.6 to 2.5 s.
- ATS4-GA control power DC 24, 48, 110 V or AC 220 V; 4-pole weight from 3.4 kg to 67 kg.
- The GA integral control covers three positions and source-failure monitoring; it gives a generator start signal after a 3 s delay when the main fails.
- In the ATS1 model code, X means economical, Y fire type, M mini type.
Using it in design
- Record each ATS current rating with the frame and discrete step (for example 200 A on ATS3-225), not only the series name.
- For data-centre critical loads, decide whether transfer times of 1.5-3 s (ATS1) or 0.6-2.5 s (ATS4-GA) will sit behind a UPS or on mechanical loads.
- Compare the ATS4-GA utilisation category and limited short-circuit current with the site short-circuit current.
- For the split controller type, add the in-panel controller position and the 2 m cable limit to the panel layout.
- Include the 3 s generator start signal delay in the generator start-up and UPS battery time calculation.
Who should read it
Electrical engineers designing mains and generator changeover, and teams writing ATS specifications.
Document contents
- ATS1 Series Automatic Transfer Switch
- ATS2 and ATS3 Series
- ATS4-GA Series
- Technical parameter tables
Publication details
- Authors
- MAXGE
- Publisher
- MAXGE
- Year
- 2025
- Document number
- 202509 V5
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document