AVO Series 5–10kVA UPS technical specifications, PDF pp.2–3
Switching AVO
A Switching AVO specification sheet giving three models of the single-phase on-line AVO series: AVO1005 at 5 kVA/5000 W, AVO1006 at 6 kVA/6000 W and AVO1010 at 10 kVA/10000 W, with efficiency of at least 94% at full load and at least 98% in ECO mode, and 0 ms transfer time between mains and battery mode.
On this page
Overview
The AVO series is a tower on-line UPS family with single-phase three-wire (phase, neutral, PE) input and output, compatible with grid or generator supply. Rated voltage is 208, 220, 230 or 240 V AC and frequency 50/60 Hz with auto-sensing. The input voltage range is 130 to 280 V AC at 45% load and the frequency range 40 to 70 Hz. Input power factor is at least 0.99 and input current distortion at most 5%. An automatic bypass switch is fitted, and the bypass voltage range is settable between -40% and +15%.
Output voltage regulation is ±1%, and voltage distortion is at most 1% on linear load and 4% on non-linear load. The sheet lists 0.8, 0.9 and 1 together on the output power factor row, while the capacity row gives equal kVA and W values for each model. At 208 V output the power factor is 0.9. On overload the unit runs continuously below 105%, for more than 10 minutes at 105% to 110%, 2 minutes at 110% to 125% and 30 seconds at 126% to 150%. For a load step from 10% to 90%, dynamic regulation is ±10% and recovery takes less than 80 ms.
The battery circuit is 192 V DC, settable between 144 and 240 V DC. Each model comes in two versions: the standard (S) version with internal batteries and the long-time (H) version that works with external batteries. Charging current is 1 A on the standard version and 5 A by default on the long-time version (settable 1 to 5 A), with 12 A optional. The H cabinet is only 350 mm high and weighs 14.5 to 16.5 kg; the S cabinet is 711 mm high and weighs 53 to 62 kg. Up to 4 units can be paralleled. The sheet notes that specifications can change without notice.
Key points
- Models: AVO1005 (5 kVA/5000 W), AVO1006 (6 kVA/6000 W), AVO1010 (10 kVA/10000 W).
- Efficiency: at least 94% at 100% load, maximum 95% at 60% load, at least 98% in ECO mode.
- Transfer time 0 ms (from mains mode to battery mode and back).
- Input power factor at least 0.99; THDi at most 5%; output THDv at most 1% on linear load and 4% on non-linear load.
- Overload: continuous below 105%, more than 10 minutes at 105% to 110%, 2 minutes at 110% to 125%, 30 seconds at 126% to 150%.
- Battery voltage 192 V DC (settable 144 to 240 V DC); charging current 1 A on the standard version, 5 A on the long-time version, 12 A optional.
- Net weight: 53 and 62 kg for the standard (S) version, 14.5 and 16.5 kg for the long-time (H) version; cabinet width 191 mm.
- Operating temperature 0 to 40 °C; noise at most 50 dB at 1 m; IP20; forced air cooling; up to 4 units in parallel.
Using it in design
- Match the load to the W value on the capacity row, and have the manufacturer confirm before ordering which condition each of the three power factor values applies to.
- For long backup, specify the H version with an external battery cabinet and check that the 5 A or 12 A charging current refills the chosen battery capacity in reasonable time.
- Calculate heat load from the 94% full-load efficiency.
- For generator operation, compare the 40 to 70 Hz input frequency range and the slew rate below 1 Hz per second with the generator's regulation.
- In dusty environments, add the optional internal air filter to the specification.
Who should read it
Engineers selecting 5 to 10 kVA single-phase UPS units for small server rooms and industrial loads, and teams preparing product catalogue data.
Document contents
- Specifications
- Input
- Output
- Batteries
- System
- Others
Publication details
- Authors
- Switching AVO
- Publisher
- Switching AVO
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Switching AVO AVO Series 5–10kVA UPS technical specifications, PDF pp.2–3. Switching AVO. https://www.switchingavo.com/img/pdf/AVO_SERIES_5-10KVA_UPS%5B2%5D.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.