TOMZN TOQ7S Wi-Fi Automatic Dual-Power Transfer Switch
Original title TOMZN TOQ7S Wi-Fi automatic dual-power transfer switch
TOMZN
The TOMZN TOQ7S is a Tuya/SmartLife Wi-Fi ATS in 63, 100 and 125 A, 2P/3P/4P, 230 V; switching time is under 50 ms, electrical life 2000 and mechanical life 5000 operations, and the Wi-Fi circuit is powered from source A.
On this page
Overview
The product page presents the TOQ7S smart ATS, which switches between mains and generator or PV and can be controlled remotely through the Tuya/SmartLife app. The app supports remote switching, countdown, timer and relay status. The title gives 2P, 3P and 4P options and 63 A, 100 A and 125 A current ratings. The device is an upgraded version of the TOQ7e series; the key difference is that the app status does not change when the power source switches.
Operating logic is described in two modes. When ON (Source A) is selected in the app, the TOQ7S works as a normal ATS: when source A loses power it switches to source B automatically, and returns to A automatically when A is restored. If source B is selected in the app, the device does not return to A automatically and stays on B, regardless of whether B is energised. On the TOQ7e, when source A is cut the app also moves to B and the device does not return to A.
Parameters: rated supply voltage 220-230 V (L-N) 50-60 Hz, working condition 85-110% Us, switching time under 50 ms, action time under 50 ms, rated impulse withstand voltage 8 kV, electrical life 2000 and mechanical life 5000 operations. The page stresses two limits: the product works only on L+N 220-230 V 50-60 Hz, and because the Wi-Fi chip is powered from source A, switching through TUYA/SmartLife is not possible when source A is lost.
Key points
- 2P, 3P and 4P options; 63, 100 and 125 A ratings; 230 V.
- Rated supply voltage 220-230 V (L-N), 50-60 Hz; working condition 85-110% Us.
- Switching time and action time under 50 ms.
- Rated impulse withstand voltage 8 kV; electrical life 2000, mechanical life 5000 operations.
- In source-A mode: on A loss it moves to B and returns automatically when A is back.
- In source-B mode: the device stays on B and does not return to A automatically.
- The Wi-Fi chip is powered from source A; app switching is unavailable when A is lost.
- Works only on L+N 220-230 V 50-60 Hz.
Using it in design
- Connect the primary source (mains) to A; because Wi-Fi depends on A, remote commands are unavailable during a mains outage, while automatic transfer to B continues to work.
- If a generator or PV is on B and B mode is selected, write into the operating procedure that the device does not return when mains is restored.
- With a 2000-operation electrical life, calculate lifetime where transfers are frequent.
- In a three-phase system, verify suitability given the L+N 220-230 V limit; the product is not defined for 400 V phase-to-phase.
- When uninterrupted transfer is needed for critical load, compare the under-50 ms switching time with the load's tolerance curve.
Who should read it
Electrical designers and integrators looking for a smart ATS for small facilities and infrastructure loads.
Document contents
- General
- Product parameters
- Notes
Publication details
- Authors
- TOMZN
- Publisher
- TOMZN
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
TOMZN TOMZN TOQ7S Wi-Fi automatic dual-power transfer switch. TOMZN. https://tomzn.com/product/tomzn-tuya-smartlife-wifi-smart-ats-dual-power-automatic-transfer-selector-switch-uninterrupted-2p-3p-4p-230v-63a-100a-125a/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.