Shenling Precision Air Conditioner Brochure (HM series), Ver.20260206

Original title Shenling Precision Air Conditioner Brochure, Ver.20260206

Shenling

The Shenling HM brochure gives air-cooled DX and chilled water in-room and in-row precision units; HM060C, HM100C and HM180C reach 54.2, 105.2 and 168.3 kW at 12/18 °C water and 61.6, 119.4 and 187.5 kW at 15/21 °C.

On this page

Overview

The document is the technical table of Shenling's HM precision air conditioner series (Ver. 20260206). It covers air-cooled in-room DX (all DC inverter), air-cooled in-row DX, water-cooled (chilled water) in-room and chilled water in-row units. 3+2 Mode and dynamic cooling are stated, with switching between compressor mode and fluorine pump mode.

The in-room DX models HM030A-HM120A give 32.4, 45.2, 62.7, 90.4 and 125.1 kW cooling (all sensible), 9,000-26,000 m³/h airflow and 340-635 kg net weight. In-row DX HM25RA-HM60RA give 26.8-62.6 kW at 5,000-12,000 m³/h. Outdoor units are the SW40-SW90 series with a standard operating range of -20 to +45 °C, or -40 to +45 °C with the low temperature kit; indoor ambient is 0-40 °C and 20-80% RH.

For the chilled water in-room HM060C, HM100C and HM180C two conditions are given. Condition 1 (30 °C dry-bulb/20 °C wet-bulb, 12/18 °C water): total capacity 54.2, 105.2 and 168.3 kW, sensible 54.0, 104.8 and 165.4 kW, water flow 8.4, 15.8 and 25.2 m³/h, pressure drop 55.0, 87.6 and 79.2 kPa. Condition 2 (35 °C dry-bulb/21.5 °C wet-bulb, 15/21 °C water): 61.6, 119.4 and 187.5 kW (all sensible), flow 9.5, 17.8 and 28.3 m³/h, pressure drop 68.4, 99.9 and 95.5 kPa. Airflow is 13,000, 25,000 and 39,000 m³/h; unit dimensions 900, 1,800 and 2,700 mm wide, 1,000 mm deep, 1,980 mm high.

The chilled water in-row HM30RC and HM80RC give 20.4 and 36.1 kW at 37 °C dry-bulb/21 °C wet-bulb and 18/24 °C water, and 21.8 and 38.6 kW at 35/21.5 °C air and 15/21 °C water. EC fan motor and proportional-integral two-way valve are standard. The tables may be updated without notice to users.

Key points

  1. HM060C, HM100C, HM180C: 54.2, 105.2 and 168.3 kW at 12/18 °C water (air 30/20 °C).
  2. The same models give 61.6, 119.4 and 187.5 kW at 15/21 °C water (air 35/21.5 °C), all sensible.
  3. Water flow 8.4-25.2 m³/h (12/18 °C) and 9.5-28.3 m³/h (15/21 °C); pressure drop 55.0-99.9 kPa.
  4. Airflow 13,000, 25,000 and 39,000 m³/h.
  5. Air-cooled in-room DX: HM030A-HM120A, 32.4-125.1 kW, full DC inverter.
  6. In-row DX HM25RA-HM60RA: 26.8-62.6 kW.
  7. In-row chilled water HM30RC and HM80RC: 20.4 and 36.1 kW (18/24 °C water).
  8. Outdoor unit operating range -20/+45 °C, -40/+45 °C with low temperature kit.
  9. EC fan motor and proportional-integral two-way valve are standard.

Using it in design

  • When selecting a chilled water model, confirm that one of the two conditions is close to your water and air temperatures; capacity rises about 11-14% between 12/18 °C and 15/21 °C water.
  • Add pressure drop (55-100 kPa) to the pump and CDU or heat exchanger head calculation.
  • Compare units on sensible capacity; at the 12/18 °C condition sensible capacity is slightly below total.
  • Carry weight and footprint (900-2,700 mm wide) into the layout plan.
  • For air-cooled DX, assess the outdoor unit operating range and fluorine pump mode against the free cooling strategy.

Who should read it

Data hall mechanical designers selecting in-room and in-row precision air conditioners.

Document contents

  1. Air-cooled in-room DX
  2. Air-cooled in-row DX
  3. Outdoor unit tables
  4. Water-cooled in-room chilled water
  5. Water-cooled in-row chilled water
  6. Product lineup

Publication details

Authors
Shenling
Publisher
Shenling
Year
2026
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Shenling (2026). Shenling Precision Air Conditioner Brochure, Ver.20260206. Shenling. https://img.shenlinghvac.com/attachment/1/file/4779/Shenling%20Precision%20Air%20Conditioner%20Brochure_Ver.20260206.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.