White paperCitation2008

WP#14 - The Green Grid Metrics: PUE/DCiE Detailed Analysis

The Green Grid · Gary Verdun, Dan Azevedo et al.

A 2008 detailed analysis paper from The Green Grid aimed at making DCiE and PUE usable as a global standard metric.

On this page

Overview

This document is The Green Grid's (TGG) white paper number 14, dated 10 December 2008, with Gary Verdun as lead author. It is a follow-on analysis supporting the DCiE metric introduced in the organisation's earlier paper 'The Green Grid Metrics: Describing Datacenter Power Efficiency'. Access requires registration; only the information on the TGG library description page was used here.

The stated aim is to strengthen DCiE and PUE so that data centre managers can derive and apply them as a global standard metric. In other words, the paper is an effort to supply the detail needed so that an efficiency ratio is not merely defined but can be calculated in the same way across different facilities and compared. The record contains no formulas or numerical examples, so this page does not go into method detail.

The paper belongs to the 2007-2009 metric-definition series that preceded the PUE v2 recommendations. It should therefore be read today as a historical source: DCiE was later set aside in favour of PUE, and the measurement categories come from the later PUE v2 and ISO/IEC 30134-2 rules. The document's value is that it traces how PUE became a standard metric.

Key points

  1. Dated 10 December 2008; lead author Gary Verdun and colleagues.
  2. Provides detailed analysis to support and strengthen the DCiE metric.
  3. Builds on TGG's earlier paper 'Describing Datacenter Power Efficiency'.
  4. Stated aim: let managers derive and use DCiE as a global standard metric.
  5. Part of the 2007-2009 metric-definition series that preceded the PUE v2 recommendations.
  6. DCiE was later deprecated in favour of PUE; measurement categories come from PUE v2 and ISO/IEC 30134-2.
  7. Registration required; related standard ISO/IEC 30134-2.

Using it in design

  • Use this document as a historical reference when examining the development of PUE and DCiE definitions.
  • When interpreting historical DCiE values, note that current reporting favours PUE.
  • Take measurement categories from the later PUE v2 and ISO/IEC 30134-2 rules, not from this paper.

Who should read it

Energy-efficiency specialists and tool developers who want to understand the origin and development of PUE and DCiE.

Related standards

  • ISO/IEC 30134-2

Publication details

Authors
Gary Verdun; Dan Azevedo; Nick Gruendler; Hugh Barrass; Bob MacArthur; Stephen Berard; Phil Morris; Mark Bramfitt; Andy Rawson; Tahir Cader; Jim Simonelli; Tommy Darby; Harkeeret Singh; Christine Long; John Wallerich
Publisher
The Green Grid
Year
2008
Document number
WP 14
Document language
English
Source type
Industry body
Access
Citation only
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Download requires a free TGG account sign-in and is governed by The Green Grid Terms of Use; summary and facts from the public library landing page; full text not redistributed.

Citation

Gary Verdun; Dan Azevedo; Nick Gruendler; Hugh Barrass; Bob MacArthur; Stephen Berard; Phil Morris; Mark Bramfitt; Andy Rawson; Tahir Cader; Jim Simonelli; Tommy Darby; Harkeeret Singh; Christine Long; John Wallerich (2008). WP#14 - The Green Grid Metrics: PUE/DCiE Detailed Analysis. The Green Grid. WP 14. https://www.thegreengrid.org/resources/library-and-tools/green-grid-metrics-puedcie-detailed-analysis

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.