Technical guideCitation2024

TGG's Liquid Cooling TCO v4 Calculation Tool (Version 4.1)

The Green Grid · The Green Grid, Liquid Cooling Standing Work Group

The Green Grid's spreadsheet tool, posted 24 January 2024, compares total cost of ownership of air and liquid cooling architectures; version 4.1 adds a workload-dependent liquid cooling efficiency metric.

On this page

Overview

The tool is a spreadsheet developed by The Green Grid's Liquid Cooling Standing Work Group and presented for review by TGG members. It compares total cost of ownership (TCO) of air and liquid cooling architectures and is the calculator that the library's WP#91 handbook documents. Download requires a sign-in.

Version 4.1 adds seven parameters to V3: liquid cooling efficiency (LCE) by workload type alongside PUE, which is independent of workload; liquid-to-air CDUs in addition to liquid-to-liquid only; closed-loop as well as open-type cooling towers; a two-phase direct-to-chip cold plate option; alcohol and natural ester secondary fluids; a building envelope selection; and a lighting source selection.

It serves teams that want capital and operating cost compared for different cooling topologies in one framework. Complementing PUE with LCE is the headline change of this version.

Key points

  1. Posted 24 January 2024 as a spreadsheet, version 4.1.
  2. Designed to compare TCO of air and liquid cooling architectures.
  3. Adds LCE by workload type alongside PUE, which does not depend on workload.
  4. Adds liquid-to-air CDUs and closed-loop cooling towers.
  5. Adds a two-phase direct-to-chip cold plate option and alcohol and natural ester secondary fluids.
  6. Adds user selection of building envelope and lighting source.
  7. Developed by the Liquid Cooling Standing Work Group.

Using it in design

  • Compare air and liquid cooling options in one TCO framework at concept stage.
  • Report efficiency by workload type with LCE, not PUE alone.
  • Model sites without facility water separately using the liquid-to-air CDU option.
  • Read results together with the assumptions in the WP#91 handbook.

Who should read it

Designers choosing a cooling architecture and finance and operations teams doing investment analysis.

Related standards

  • TGG WP#91 Liquid Cooling TCO tool Handbook

Publication details

Authors
The Green Grid, Liquid Cooling Standing Work Group
Publisher
The Green Grid
Year
2024
Document language
English
Source type
Industry body
Access
Citation only
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Download requires sign-in and acceptance of The Green Grid Terms of Use; page states all rights reserved.

Citation

The Green Grid, Liquid Cooling Standing Work Group (2024). TGG's Liquid Cooling TCO v4 Calculation Tool (Version 4.1). The Green Grid. https://www.thegreengrid.org/en/resources/library-and-tools/577-TGG%27s-Liquid-Cooling-TCO-Calculation-Tool-%28V4%29

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.