WP#75 - Server Energy Efficiency in Data Centers and Offices

The Green Grid · Jay Dietrich, Jeff Doolittle et al.

The Green Grid's 2017 white paper comparing idle-power and SERT-based active-efficiency metrics as regulatory measures of server efficiency.

On this page

Overview

This white paper compares idle-power and SERT-based active-efficiency metrics as regulatory measures of server efficiency, using a deployed-power methodology. It is dated 7 November 2017 and edited by Jay Dietrich (IBM). Related documents include ISO/IEC 21836 (SERT) and Regulation (EU) 2019/424.

The deployed-power method uses SERT data to find the server count and power for a target workload. The paper finds that idle-power limits would exclude high-performance servers and could raise data-centre energy; per the abstract's Figure 12, idle-power regulation could result in over 30% higher data-centre energy. The Green Grid advocates the weighted geomean active-efficiency metric based on SERT.

The information comes only from the public description page of The Green Grid library; the full text requires signing in with a free account and is governed by the Terms of Use. It should be kept in mind that the paper reflects an industry body's position and takes a side in the regulatory debate.

Key points

  1. Dated 7 November 2017; editor Jay Dietrich (IBM).
  2. The deployed-power method uses SERT data to find server count and power for a target workload.
  3. Idle-power regulation could result in over 30% higher data-centre energy (paper Figure 12).
  4. Idle-power limits would exclude high-performance servers.
  5. Recommends weighted geomean active efficiency based on SERT.
  6. Related: ISO/IEC 21836 (SERT) and Regulation (EU) 2019/424.
  7. Full text requires a free TGG account.

Using it in design

  • In the server catalogue, store the SERT active-efficiency score together with idle power.
  • Size the IT load from workload and performance, not from idle power alone.
  • When comparing server options, base the comparison on deployed power (server count x power) for the same workload.

Who should read it

Designers selecting servers and sizing IT load, and energy specialists following regulatory developments.

Related standards

  • ISO/IEC 21836 (SERT)
  • Regulation (EU) 2019/424

Publication details

Authors
Jay Dietrich; Jeff Doolittle; Gary Verdun; Shahid Sheikh; David Reiner; Henry Wong
Publisher
The Green Grid
Year
2017
Document number
WP 75
Document language
English
Source type
Industry body
Access
Citation only
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Download requires a free TGG account sign-in and is governed by The Green Grid Terms of Use; summary and facts from the public library landing page; full text not redistributed.

Citation

Jay Dietrich; Jeff Doolittle; Gary Verdun; Shahid Sheikh; David Reiner; Henry Wong (2017). WP#75 - Server Energy Efficiency in Data Centers and Offices. The Green Grid. WP 75. https://www.thegreengrid.org/en/resources/library-and-tools/496-WP%2375---Server-Energy-Efficiency-in-Data-Centers-and-Offices

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.