RegulationCitation2024

WP#92 - TGG's Position on the Metric to Calculate ICT Server Capacity (Cserv) Under the EU EED Delegated Regulation (2024/1364)

The Green Grid · TGG ITE External Metrics Work Group

The Green Grid's October 2024 position paper proposes PerfCPU as the standard metric for ICT server capacity (Cserv) under the EU EED reporting regulation.

On this page

Overview

WP#92 is a Green Grid position paper dated 16 October 2024, prepared by the TGG ITE External Metrics Work Group. The paper's context is Delegated Regulation 2024/1364 under the EU Energy Efficiency Directive (EED). That regulation sets the reporting scheme for data centres, and among the quantities to be reported is ICT server capacity (Cserv). The paper sets out the industry view on how Cserv should be calculated.

The core of the proposal is the use of PerfCPU as the metric for Cserv. PerfCPU is the maximum CPU performance defined by the equation in Section 5.2 of ETSI EN 303 470. Server capacity is thereby expressed as a value that rests on an existing standard and can be calculated per server model.

Limits: this is the position paper of an industry body, not a binding regulation, and its full text was not read, so the details of the equation and the reasoning are absent from this record. For designers and operators its value is in showing one way to fill the Cserv field in EED reporting.

Key points

  1. Dated 16 October 2024; paper of the TGG ITE External Metrics Work Group.
  2. Proposes PerfCPU as the metric for Cserv.
  3. PerfCPU is defined by the equation in EN 303 470 Section 5.2.
  4. Context: EU EED Delegated Regulation 2024/1364.
  5. Related standards: Delegated Regulation (EU) 2024/1364 and ETSI EN 303 470.

Using it in design

  • Include Cserv calculated from PerfCPU per server SKU in the EED report.
  • State the source of the PerfCPU value (EN 303 470 Section 5.2) in the report.
  • Note in the reporting notes that the paper is a position, not a binding method.
  • Keep the Cserv calculation configurable so it can be updated if the regulator's final method changes.

Who should read it

Data centre operators doing EED reporting in the EU and teams building reporting tools.

Related standards

  • Delegated Regulation (EU) 2024/1364
  • ETSI EN 303 470

Publication details

Authors
TGG ITE External Metrics Work Group
Publisher
The Green Grid
Year
2024
Document number
WP 92
Document language
English
Source type
Industry body
Access
Citation only
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Download requires a free TGG account sign-in and is governed by The Green Grid Terms of Use; summary and facts from the public library landing page; full text not redistributed.

Citation

TGG ITE External Metrics Work Group (2024). WP#92 - TGG's Position on the Metric to Calculate ICT Server Capacity (Cserv) Under the EU EED Delegated Regulation (2024/1364). The Green Grid. WP 92. https://www.thegreengrid.org/resources/library-and-tools/wp92-tggs-position-metric-calculate-ict-server-capacity-cserv-under-eu

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.