Low-voltage switchgear and controlgear assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO)
IEC · IEC TC 121
The IEC 61439 product part for small final distribution boards that ordinary persons may operate (switching, replacing fuse-links); the 2024 second edition replaces the 2012 edition.
On this page
Overview
IEC 61439-3:2024 is the product part of the low-voltage assemblies family devoted to distribution boards that ordinary persons may operate (DBO). Such persons can perform switching and replace fuse-links. Typical examples are small final distribution boards. The second edition was published on 26 March 2024, runs to 130 pages and replaces the 2012 edition; a commented version is also available.
The scope limits are clear from the publication abstract: nominal voltage to earth does not exceed 300 V AC (DC limits are under consideration). Outgoing circuits may be rated up to 125 A (Inc) and the assembly up to 250 A (InA). The outgoing circuits are fitted with protective devices such as those under IEC 60898-1, IEC 61008/61009, IEC 62606, IEC 62423 and IEC 60269-3.
This part is not read on its own; it is applied together with IEC 61439-1, which holds the general rules, and it has a Turkish counterpart as TS EN 61439-3. For power assemblies, the separate product part IEC 61439-2 applies.
Key points
- Covers assemblies operated by ordinary persons: switching operations and replacing fuse-links.
- Outgoing circuits use protective devices such as IEC 60898-1, IEC 61008/61009, IEC 62606, IEC 62423, IEC 60269-3.
- Nominal voltage to earth not exceeding 300 V AC; DC limits under consideration.
- Outgoing circuit rated current Inc <= 125 A; assembly rated current InA <= 250 A.
- Edition 2 published 26 March 2024 (130 pages); replaces the 2012 edition.
- Applied with IEC 61439-1; the Turkish counterpart is TS EN 61439-3.
- Power assemblies are covered separately by IEC 61439-2.
Using it in design
- Board selection rule: allow the DBO type only for office/support-area final boards within the 250 A/125 A limits.
- Specify IT-room boards operated only by skilled persons as PSC (Part 2) or BTS tap-offs.
- State in board specifications which part of IEC 61439 applies.
- Check the voltage limit: applications above 300 V AC to earth fall outside this part.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Review your power design in SoSo CAD
Inspect supply paths, equipment loads and UPS failure scenarios in one model.
Request a demo
Who should read it
Electrical design engineers selecting and specifying low-voltage distribution boards.
Related standards
- IEC 61439-1
- IEC 61439-2
- TS EN 61439-3
Publication details
- Authors
- IEC TC 121
- Publisher
- IEC
- Year
- 2024
- Document number
- IEC 61439-3:2024
- Document language
- English
- Source type
- Standard
- Access
- Citation only
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note
Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.
Citation
IEC TC 121 (2024). Low-voltage switchgear and controlgear assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO). IEC. IEC 61439-3:2024. https://webstore.iec.ch/en/publication/93494
Events on this subject
- Electricity Eurasia 2027
- ELECO 2026 Elektrik-Elektronik ve Biyomedikal Mühendisliği Konferansı
- 7x24 Exchange Spring Conference
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.