Technical guideCitation2021

Power Supply Efficiency Comparison at 380VDC versus 230VAC

The Green Grid · Jason Boehlke, Colleen Collins

A Green Grid presentation comparing the measured efficiency of identical server power supplies at 230 V AC and 380 V DC.

On this page

Overview

This document is a Green Grid presentation dated 24 May 2021, presented by Jason Boehlke and Colleen Collins. Its purpose is to determine whether separate test criteria are warranted for 380 V DC server power supplies (PSUs).

The method is simple: data from roughly 30 units, each tested at both 230 V AC and 380 V DC. Because the same units are compared, their efficiencies can be set side by side directly, and noise from differences between units is reduced. The framework gives measured context to claims about the efficiency of DC distribution. The roughly 30-unit sample gives a more dependable context than inference from a single device, though its size and scope are limited to what the summary page states.

As a presentation it is a short source, and the landing page does not give numerical results. This page therefore claims no particular efficiency difference. The document should be read as context for not assuming a large PSU efficiency gain at 380 V DC compared with 230 V AC. It does not weigh every advantage and drawback of DC distribution; it addresses only the power-supply efficiency dimension.

Key points

  1. Presentation dated 24 May 2021 by Jason Boehlke and Colleen Collins.
  2. Purpose: determine whether test criteria for 380 V DC PSUs are warranted.
  3. Data from roughly 30 units.
  4. Each unit tested at both 230 V AC and 380 V DC.
  5. Comparing identical units removes differences between units from the measurement.
  6. The public summary gives no numerical results.

Using it in design

  • In AC-vs-DC comparisons, do not assume a large PSU efficiency gain at 380 V DC.
  • Model PSU efficiency as an input with a default similar to high-line AC unless the user supplies measured data.
  • Back efficiency arguments for DC distribution proposals with measured data.
  • State the PSU models and test conditions in the comparison report.

Monthly newsletter · free

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.

SoSo CAD

Review your power design in SoSo CAD

Inspect supply paths, equipment loads and UPS failure scenarios in one model.

Request a demo
Single-line diagram in the SoSo CAD power and capacity workspace

Who should read it

Electrical design engineers comparing AC and DC power distribution, and teams selecting IT power supplies.

Publication details

Authors
Jason Boehlke; Colleen Collins
Publisher
The Green Grid
Year
2021
Document language
English
Source type
Industry body
Access
Citation only
Licence
Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note

Download requires a free TGG account sign-in and is governed by The Green Grid Terms of Use; summary and facts from the public library landing page; full text not redistributed.

Citation

Jason Boehlke; Colleen Collins (2021). Power Supply Efficiency Comparison at 380VDC versus 230VAC. The Green Grid. https://www.thegreengrid.org/en/resources/library-and-tools/525-Power-Supply-Efficiency-Comparison-at-380VDC-versus-230VAC

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.