WP#31 - Issues Relating to the Adoption of Higher Voltage Direct Current Power in the Data Center
The Green Grid · The Green Grid Power Sub Work Group
A 2010 Green Grid white paper discussing the cost-effectiveness, ease-of-adoption and safety issues that must be resolved before higher-voltage DC (HVdc) can become a primary data centre distribution option.
On this page
Overview
WP#31 is a white paper prepared by The Green Grid's Power Sub Work Group, dated 20 October 2010. Its subject is the issues that must be resolved before higher-voltage direct current (HVdc) can become a primary distribution option in the data centre. Downloading the full text requires signing in with a free The Green Grid account and is governed by The Green Grid Terms of Use; the information in this record comes from the summary on the library's public landing page.
According to the abstract, HVdc distribution can reduce energy consumption and increase efficiency. For this potential to be realised, however, critical issues of cost-effectiveness, ease of adoption and safety must be resolved. The paper makes clear that these topics were not yet mature, meaning HVdc was not a ready alternative but an option that needed work. The paper should therefore be read as an assessment of the barriers to adoption rather than a product pitch, and the source text should be consulted for full detail.
An important recommendation of the paper is the establishment of global HVdc standards. The aim is to avoid the fragmentation seen with alternating current (AC) systems repeating on the DC side. Without common standards, equipment compatibility, protection and connectors could lead to supplier dependence and added cost. The record lists ETSI EN 300 132-3 and IEC 60364 among related documents.
The limits of the document are clear. It is a 2010 study, and HVdc technology, the product ecosystem and standards may have developed since. Only the public abstract is used here, so numerical detail on losses, cost or safety measures is not part of this record. The paper should therefore be used for the historical and conceptual framing of HVdc, and current decisions should rely on current standards and manufacturer data.
Key points
- Dated 20 October 2010; authored by the Power Sub Work Group.
- HVdc distribution can reduce energy consumption and increase efficiency.
- Critical issues of cost-effectiveness, ease of adoption and safety must be resolved.
- Recommends establishing global HVdc standards to avoid the fragmentation seen with AC.
- Related documents: ETSI EN 300 132-3 and IEC 60364.
Using it in design
- If the tool offers 380 V DC topologies, flag them as requiring DC-rated protection devices and connectors.
- Compare conversion-stage counts of DC topologies against AC topologies.
- When assessing an HVdc option, record standards maturity and supplier diversity as a risk item.
- Review safety requirements (fault current interruption, earthing) separately for DC.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Review your power design in SoSo CAD
Inspect supply paths, equipment loads and UPS failure scenarios in one model.
Request a demo
Who should read it
Designers evaluating electrical distribution architecture and engineers exploring the efficiency potential of DC power distribution.
Related standards
- ETSI EN 300 132-3
- IEC 60364
Publication details
- Authors
- The Green Grid Power Sub Work Group
- Publisher
- The Green Grid
- Year
- 2010
- Document number
- WP 31
- Document language
- English
- Source type
- Industry body
- Access
- Citation only
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note
Download requires a free TGG account sign-in and is governed by The Green Grid Terms of Use; summary and facts from the public library landing page; full text not redistributed.
Citation
The Green Grid Power Sub Work Group (2010). WP#31 - Issues Relating to the Adoption of Higher Voltage Direct Current Power in the Data Center. The Green Grid. WP 31. https://www.thegreengrid.org/en/resources/library-and-tools/391-WP%23-31---Issues-Relating-to-the-Adoption-of-Higher-Voltage-Direct-Current-Power-in-the-Data-Center
Events on this subject
- Electricity Eurasia 2027
- ELECO 2026 Elektrik-Elektronik ve Biyomedikal Mühendisliği Konferansı
- The smarter E Europe (Intersolar Europe, ees Europe, Power2Drive, EM-Power)
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.