White paperCitation2010

WP#34 - The Green Grid Data Center Compute Efficiency Metric: DCcE

The Green Grid · Mark Blackburn, Dan Azevedo et al.

A 2010 Green Grid white paper proposing Data Center Compute Efficiency (DCcE) and its sub-metric Server Compute Efficiency (ScE) to quantify how efficiently compute resources are used.

On this page

Overview

WP#34 is a white paper published by The Green Grid on 20 December 2010, with Mark Blackburn (1E) as editor. It defines the Data Center Compute Efficiency (DCcE) metric and its sub-metric Server Compute Efficiency (ScE). The aim is to quantify how efficiently compute resources are used. The full text requires signing in with a free The Green Grid account; this record is based on the summary on the public landing page.

The metric's focus is the IT side rather than the infrastructure. While PUE measures the energy efficiency of facility infrastructure, DCcE is intended to do for IT what PUE does for infrastructure. This lets operators locate where inefficiency lies in compute resources. A facility may have a good PUE, yet if its servers run at low utilisation, inefficiency can persist in another layer.

According to the paper, the metric is meant for continuous refinement in the same way as PUE; it is not a one-off assessment but an indicator tracked and improved over time. As a design implication, the record suggests an optional IT efficiency panel in which the user enters server utilisation data and sees an ScE/DCcE-style indicator beside PUE. Given these caveats, the paper should be treated as a conceptual framework.

It is a 2010 study, and the calculation form of the metric, accepted threshold values and example results are not part of the public summary. This record therefore does not contain formula details; these must be verified from the paper itself. Whether the metric has been widely adopted in the industry cannot be inferred from this record.

Key points

  1. Dated 20 December 2010; editor Mark Blackburn (1E).
  2. Defines DCcE and its sub-metric ScE.
  3. Lets operators locate inefficiency in compute resources.
  4. Intended to do for IT what PUE does for infrastructure.
  5. Intended to be used for continuous refinement, analogous to PUE.

Using it in design

  • In an optional IT efficiency panel, allow users to enter server utilisation data.
  • Display an ScE/DCcE-style indicator beside PUE.
  • In low-utilisation scenarios, state in the report that a good PUE alone does not mean efficiency.
  • Verify the metric's definition from the paper before implementing its formula.

Monthly newsletter · free

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.

SoSo CAD

Compare the cost of design decisions

Evaluate equipment costs, energy expenses and total cost of ownership (TCO) using your inputs and assumptions in SoSo CAD.

Request a demo
CAPEX and TCO estimates in the SoSo CAD cost workspace

Who should read it

Designers, operations managers and sustainability reporters who evaluate IT and facility efficiency together.

Publication details

Authors
Mark Blackburn; Dan Azevedo; Andy Hawkins; Zeydy Ortiz; Roger Tipley; Sven Van Den Berghe
Publisher
The Green Grid
Year
2010
Document number
WP 34
Document language
English
Source type
Industry body
Access
Citation only
Licence
Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note

Download requires a free TGG account sign-in and is governed by The Green Grid Terms of Use; summary and facts from the public library landing page; full text not redistributed.

Citation

Mark Blackburn; Dan Azevedo; Andy Hawkins; Zeydy Ortiz; Roger Tipley; Sven Van Den Berghe (2010). WP#34 - The Green Grid Data Center Compute Efficiency Metric: DCcE. The Green Grid. WP 34. https://www.thegreengrid.org/en/resources/library-and-tools/240-WP%23-34---The-Green-Grid-Data-Center-Compute-Efficiency-Metric%3A-DCcE

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.