Technical guideFree to read2022

06 Soğutma 2022 catalogue: chillers, cooling towers and dry coolers

Original title 06 Soğutma Product Catalogue 2022: Chillers, Cooling Towers and Dry Coolers

06 Soğutma

The 06 Soğutma 2022 catalogue lists R407C packaged PTS chillers of 14-600 kW, cooling towers from 22,500 to 1,800,000 kcal/h and 35-1,500 kW dry coolers (thermoconvectors).

On this page

Overview

This 2022 product catalogue from Turkish manufacturer 06 Soğutma covers five product families in Turkish and English: packaged chillers, cooling towers, milk-cooling ice machines (ice banks), thermoconvectors (dry coolers) and related tables. The company was founded in 1997. The devices are presented for industrial facilities with low-capacity chilled-water needs, plastic injection, extrusion and closed-circuit air-conditioning systems.

PTS chillers offer 14-600 kW cooling capacity. Each unit has two independent cooling circuits, R407C refrigerant, shell and tube evaporator, semi-hermetic reciprocating or screw compressors (scroll in the small models), automatic compressor rotation, flow switch and protection against +/-15% voltage irregularity and phase loss. The technical table starts with model 06 PTS 03 (15 kW, 13,000 kcal/h, 5 HP scroll) and gives compressor power, fan and dimension data.

Cooling towers run from 06 AFK 13 (22,500 kcal/h, 2.7-4.5 m³/h) to the triple 06 AFK 37x3 (1,800,000 kcal/h), with flow range, empty and full weight, fan diameter and motor power for each model. Thermoconvectors (dry coolers) cover 35-1,500 kW; being closed circuit, water loss is 1/50 of a tower and the fans switch off automatically below 20 °C outdoor temperature. The table lists 06 KSÜ 01 to 05 at 30,000-150,000 kcal/h.

The catalogue is a manufacturer product list; it gives no data-centre application, efficiency (EER) or rating conditions. It can be used in an option screening for small data rooms or auxiliary cooling.

Key points

  1. PTS packaged chiller capacity 14-600 kW; the table's 06 PTS 03 is 15 kW (13,000 kcal/h).
  2. Two independent cooling circuits, R407C, shell and tube evaporator; scroll compressors in small models, semi-hermetic in larger ones.
  3. Automatic compressor rotation, flow switch, low/high pressure switches, +/-15% voltage and phase-loss protection.
  4. Cooling towers range from 06 AFK 13 (22,500 kcal/h) to 06 AFK 37x3 (1,800,000 kcal/h).
  5. The 06 AFK 37 is 595,000 kcal/h, 59.5 m³/h (min) to 119 m³/h (max) flow, 1,160 kg empty.
  6. Thermoconvector (dry cooler) 35-1,500 kW; water loss is 1/50 of a tower.
  7. Dry cooler fans switch off automatically when outdoor temperature falls below 20 °C.
  8. The catalogue also lists milk-cooling ice machines of 5-100 tons per day.

Using it in design

  • For small data rooms or auxiliary chilled-water needs, pre-screen the PTS range by capacity and ask the manufacturer for EER and rating conditions.
  • Match the two independent circuits and automatic compressor rotation to your part-load and redundancy needs; plan unit count separately if N+1 is required.
  • To cut water loss, compare the dry cooler option (1/50 of tower water loss) with a tower on annual water use and fan energy.
  • Capacities are given in kcal/h; convert to kW and check rating conditions before comparing.
  • In tower selection, use the flow range and empty/full weights as inputs to roof or floor structure.

Who should read it

Mechanical designers screening local chiller, tower and dry-cooler options for small-scale process, auxiliary or data-room cooling.

Document contents

  1. About us
  2. Packaged water chiller
  3. Cooling tower
  4. Milk-cooling ice machine
  5. Thermoconvector (dry cooler)

Publication details

Authors
06 Soğutma
Publisher
06 Soğutma
Year
2022
Document language
Turkish
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

06 Soğutma (2022). 06 Soğutma Product Catalogue 2022: Chillers, Cooling Towers and Dry Coolers. 06 Soğutma. https://06sogutma.com/wp-content/uploads/2022/03/06-SOGUTMA-A4-KATALOG-2022.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.