Torres de Resfriamento de Água Série AP (AP series FRP cooling tower design)

Original title Torres de Resfriamento de Água Série AP

Alpina

The Alpina AP series is a line of compact, fully fibreglass-reinforced polyester (FRP) water cooling towers of Balcke Dürr origin, sized 10-54.5 m², with film or splash-bar fill options.

On this page

Overview

Alpina Equipamentos presents the AP series as the design that shaped the image of compact medium-size water cooling towers in Europe and Brazil. The original design was created by Balcke Dürr of Germany, which kept a technical cooperation contract with Alpina for more than 30 years with extensive technology transfer.

The towers are unitary, self-supporting and made entirely of fibreglass-reinforced polyester (FRP), with an FRP basin and sizes from 10 to 54.5 m². Fans are Alpina-made; a special blade profile gives low noise and high airflow at lower speeds than usual market fans. They are driven by mechanical gear motors above the tower top; optional ladders and walkways give maintenance access. Standard motors have IPW-55 protection and meet or exceed Brazilian energy-efficiency norms.

Fill is chosen by water quality: compact film type for clean water, splash-bar type for polluted water. Drift eliminator options are double-wave PVC (self-extinguishing material) or single-wave polypropylene (high water temperature). The distribution system uses FRP laminate or PVC pipes; polypropylene hot-water distributors work at very low pressure. Hardware is protected by hot-dip galvanising or epoxy and the standard colour is Munsell 10 GY 3/4 green. The page has no full model rating table; a catalogue download is offered.

Key points

  1. AP towers are fully FRP (fibreglass-reinforced polyester) with an FRP basin.
  2. Size range is 10 to 54.5 m².
  3. Original design by Balcke Dürr (Germany); more than 30 years of technical cooperation with Alpina.
  4. Fans are Alpina-made; low noise and high airflow at low speed.
  5. Standard motor protection IPW-55; special motors on request.
  6. Fill: film for clean water, splash-bar for polluted water.
  7. Drift eliminators: double-wave PVC or single-wave polypropylene for high temperature.
  8. Steel hardware is hot-dip galvanised or epoxy coated; standard colour Munsell 10 GY 3/4.

Using it in design

  • If water is dirty or carries particles, choose splash-bar fill instead of film and plan filtration with it.
  • For high-temperature water specify single-wave polypropylene drift eliminators; use double-wave PVC where self-extinguishing material is required.
  • Write the ladder and walkway option for the tower-top mechanical group into the specification according to maintenance access needs.
  • Request the model rating table from the manufacturer; the page gives only the size range (10-54.5 m²).

Who should read it

Mechanical designers specifying open-circuit cooling tower materials and fill for data-centre and industrial plants.

Document contents

  1. Torres de Resfriamento de Água Série AP
  2. Fans and drive
  3. Fill
  4. Drift eliminators
  5. Distribution system
  6. Corrosion protection and colour
  7. Downloads: catalogue

Publication details

Authors
Alpina
Publisher
Alpina
Year
Year not stated
Document language
Portuguese
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Alpina Torres de Resfriamento de Água Série AP. Alpina. https://www.alpinaequipamentos.com.br/produto/torres-de-resfriamento-de-agua/serie-ap/1

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.