Alpina AP Series Cooling Towers (Catalogue, January 2026)

Original title Alpina Torres de Resfriamento Série AP

Alpina

A January 2026 Alpina catalogue for the AP series, a counterflow cooling tower built entirely in fibreglass-reinforced polyester (FRP), describing casing, basin, fan, drift eliminators and options.

On this page

Overview

The catalogue describes the construction of Alpina's long-established AP cooling tower. The tower is counterflow: air enters from four sides and is discharged vertically. Casing, cold-water basin and internal structure are all FRP, which the maker presents as resistant to corrosion and oxidation. Models are fully demountable to ease transport and installation.

Components are described one by one. The basin has a flanged outlet, drain, make-up and overflow points, and an outlet strainer that prevents air suction. The drive group uses a TEFC motor (IP(W) 55, class F insulation, category N) and a geared reducer. Water is distributed by polypropylene nozzles under gravity; fans are axial with blade angle adjustable at standstill and balanced to ISO 1940 grade G 6.3.

Drift eliminators are removable blocks of two-stage extruded PVC or injection-moulded PP. Options include a quick-fill valve, a floorless version for concrete basins, raised air-inlet windows for obstructed sites, a low-noise version and an access ladder to the drive group.

The document contains no per-model capacity or dimension table; selection requires sending project data to the manufacturer. The data requested are number of towers, flow per tower, hot and cold water temperature, wet-bulb temperature, altitude, permitted noise level, water quality, process and installation area.

Key points

  1. Counterflow tower, vertical discharge, air inlet on four sides.
  2. Casing, basin and structure entirely FRP; standard colour dark green, others on request.
  3. Drive motor TEFC, IP(W) 55, class F insulation, category N; geared reducer.
  4. Fan balancing to ISO 1940 G 6.3; blade angle adjustable at standstill.
  5. Drift eliminator blocks of two-stage PVC or injection PP, removable.
  6. Options: low-noise version, raised air-inlet windows, floorless model, ladder.
  7. No model table; ten project inputs (flow, temperatures, wet bulb, altitude, noise limit and others) are required for a quotation.

Using it in design

  • Prepare the input list to send to the manufacturer (flow, hot/cold water, wet bulb, altitude, noise limit, water quality) as design data.
  • Check the raised air-inlet option and four-side intake clearances where walls or obstructions are close.
  • Verify capacity at the summer wet-bulb condition; specify the low-noise version separately if a noise limit applies.
  • Carry basin connection sizes and the concrete-basin need (floorless model) into the civil package.

Who should read it

Mechanical designers selecting cooling towers and engineers writing specifications.

Document contents

  1. AP series general characteristics
  2. Main benefits
  3. Construction and casing
  4. Cold-water basin
  5. Drive group
  6. Water distribution
  7. High-efficiency fans
  8. Drift eliminators
  9. Information required for a quotation

Publication details

Authors
Alpina
Publisher
Alpina
Year
Year not stated
Document language
French
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Alpina Alpina Torres de Resfriamento Série AP. Alpina. https://www.alpinaequipamentos.com.br/images/produtos/ALPINA_CATALOGO_TORRE_AP_jan26_V3.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.