ANGES AGS-120ASH: 120HP industrial air-cooled screw chiller, specification
Original title ANGES AGS-120ASH: 120HP industrial air-cooled screw chiller, Specification
ANGES
ANGES/SZAGS product page for the AGS-120ASH: a single-circuit air-cooled chiller with one semi-hermetic screw compressor, stating 382.8 kW nominal cooling capacity and 125 kW input power.
On this page
Overview
The page presents the AGS-120ASH of the ANGES (SZAGS) brand. The unit is air-cooled with a single refrigerant circuit and one semi-hermetic screw compressor. In the published table the nominal cooling capacity is 382.8 kW (329,208 kcal/h), input power 125 kW, maximum running current 283.7 A and supply 3-phase 440 V 60 Hz.
Nominal capacity is given for chilled-fluid inlet 17 °C and outlet 12 °C; evaporator flow is 65.8 m3/h with a 5 inch connection. Compressor power is 106.5 kW, starting is star-delta and capacity steps are 0-25-50-75-100. The condenser is copper tube with aluminium fin, air flow 122,000 m3/h and fan power 18 kW; the evaporator is shell and tube.
Listed features include refrigerant options (R407C, R410A, R134A, R22), PID control to ±0.1 °C and a Siemens PLC controller. Dimensions are 4200 x 2200 x 2383 mm, net weight 3250 kg and running weight 3460 kg. Protections listed cover over-temperature, overload, high/low pressure, flow switch, phase failure and anti-freeze.
The page targets industrial uses such as plastics, metalworking, chemical, food, pharmaceutical and HVAC; it contains no data-centre-specific assessment and no seasonal efficiency (EER/SEER) value. The data come from a manufacturer trade page and cover a single operating point.
Key points
- Nominal cooling capacity 382.8 kW (329,208 kcal/h), input power 125 kW.
- Nominal condition: chilled fluid 17 °C in, 12 °C out; flow 65.8 m3/h.
- Supply 3-phase 440 V 60 Hz, maximum current 283.7 A, star-delta start.
- One semi-hermetic screw compressor, 106.5 kW; capacity steps 0-25-50-75-100.
- Condenser air flow 122,000 m3/h, fan power 18 kW.
- Dimensions 4200 x 2200 x 2383 mm; net 3250 kg, running 3460 kg.
- Refrigerant options R407C, R410A, R134A, R22; control accuracy PID ±0.1 °C.
Using it in design
- Compare the 17/12 °C water pair in the table with the design water regime (for example a warmer data-hall loop); capacity changes at other conditions.
- Use input power and the 283.7 A maximum current for generator and UPS sizing and the starting-current calculation.
- Check roof or floor load and service clearance against the running weight (3460 kg) and dimensions.
- Confirm the voltage (440 V 60 Hz) against the site supply; a 50 Hz model or a transformer is needed otherwise.
Who should read it
Mechanical designers and purchasing engineers selecting industrial chillers.
Document contents
- Product details
- Product description
- Specification table
- Dimensions and weights
- Technical support and services
Publication details
- Authors
- ANGES
- Publisher
- ANGES
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
ANGES ANGES AGS-120ASH: 120HP industrial air-cooled screw chiller, Specification. ANGES. https://agschiller.com/sale-52060539-120hp-high-efficiency-industrial-air-cooled-screw-chiller-for-optimal-cooling-solutions.html
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.