BEO Modular Chiller Systems: Technical Table

Original title BEO Modüler Chiller Sistemleri: Teknik Tablo

BEO Chiller

BEO Modular Chiller product page: air-cooled modules from 10 kW to 200 kW in 5 kW steps, with scroll compressors on R410A/R407C, and per-model compressor counts.

On this page

Overview

The page presents BEO Chiller's modular chiller family and its model table. A modular system joins independent units to act as one; capacity is raised by adding modules instead of replacing the whole system. The maker states that this lets energy use follow the load and that the other modules keep running if one fails.

Technical features are: capacity range 10-200 kW (5 kW steps; 10 kW steps after 150 kW in the table), R410A or R407C refrigerant, scroll compressor, air-cooled microchannel or copper-aluminium condenser, plate heat exchanger evaporator, microprocessor control (touch screen optional), EER of 3.1-3.5 and 400 V 50 Hz supply.

The model table lists code, cooling capacity and compressor count. Models BEO-MC-010 to BEO-MC-035 have 1 compressor, BEO-MC-040 to BEO-MC-100 have 2, and BEO-MC-105 to BEO-MC-200 have 4. Every row states R410A gas and 400 V / 50 Hz.

The page lists uses such as plastic injection, food, pharmaceutical, hotels, laboratories and hospitals. The EER is given as a range with no operating condition, and there are no input power, water temperature, noise or dimension data. The table therefore suits pre-sizing and choosing module count; detailed selection needs manufacturer data.

Key points

  1. Capacity range 10-200 kW; 5 kW step (10 kW step above 150 kW in the table).
  2. Scroll compressor, air-cooled condenser, plate heat exchanger evaporator.
  3. Refrigerant R410A / R407C; supply 400 V 50 Hz.
  4. EER in the range 3.1-3.5, condition not stated.
  5. Compressors: 1 for 10-35 kW, 2 for 40-100 kW, 4 for 105-200 kW.
  6. If a module fails the others keep running; capacity grows by adding modules.
  7. Microprocessor control, touch screen optional.

Using it in design

  • Meet capacity with modules rather than one large unit, and assess N+1 redundancy by module and compressor count.
  • Use the EER range only for a first estimate; request operating-point part-load data from the maker for energy calculations.
  • Compare the 10-200 kW range and module step with the data-hall or auxiliary cooling need.
  • Carry the 400 V 50 Hz supply into switchboard and cable sizing.

Who should read it

Mechanical designers choosing modular chillers and engineers evaluating redundancy arrangements.

Document contents

  1. What is a modular chiller
  2. Applications
  3. Advantages
  4. Technical features
  5. Technical table (model, capacity, compressor count, gas, voltage)

Publication details

Authors
BEO Chiller
Publisher
BEO Chiller
Year
Year not stated
Document language
Turkish
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

BEO Chiller BEO Modüler Chiller Sistemleri: Teknik Tablo. BEO Chiller. https://www.beochiller.com/our-products/beo-modular-serisi-chiller-sistemleri/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.