BROAD Power Efficient Chiller Catalogue 2018
Original title BROAD Power Efficient Chiller Catalogue 2018, printed p.2
BROAD
BROAD's selection and design manual for 520-4200 kW magnetic-bearing oil-free centrifugal chillers and packaged pump sets, with rated COP of 5.45-6.32 and IPLV-based COP of 9.35-10.36.
On this page
Overview
The document is the selection and design manual for BROAD's electric, magnetic-bearing, oil-free centrifugal chillers (C models) and the CY packaged system that bundles pumps, valves and piping. Capacity runs from 520 to 4200 kW (150-1200 RT) and chilled water is produced above 3 °C. The manufacturer briefly explains why it builds an electric product alongside its non-electric absorption chillers.
The technical section describes the cycle at 7 °C evaporation, 45 °C condensation, 12/7 °C chilled water and 30/35 °C condenser water. For seven models (C45 to C360) it tabulates capacity, input power, rated COP, IPLV, flow, pressure drop, connection size, R134a charge and weights. In the CY package the chilled and condenser water pumps appear on separate lines with external head and power.
The catalogue also covers dimensions, a P&I diagram, scope of supply, machine-room construction tips, controls, external wiring, and lifting and levelling. A simple ratio method is given for correcting COP at part load.
This is a manufacturer catalogue; efficiency and saving claims (for example 40% energy saving against traditional electric chillers) are the maker's own statements, not certified data at standard conditions. For a data-centre designer the value is in the capacity steps, pump power and package weights for pre-sizing.
Key points
- Capacity range 520-4200 kW (150-1200 RT); seven models: C45, 60, 90, 120, 180, 240, 360.
- Rated COP runs from 5.45 (C45) to 6.32 (C360); COP at IPLV runs from 9.35 to 10.36.
- Input power is 95.5 kW for C45 and 665 kW for C360; maximum operating current 180-1380 A, starting current 2 A.
- Rated conditions: chilled water 12/7 °C, condenser water 30/35 °C, lowest chilled-water outlet 3 °C, refrigerant R134a.
- C45 ships at 2600 kg and operates at 3000 kg; C360 at 20000 and 22400 kg.
- The CY package pump set has a total power demand from 19 kW (CY45) to 150 kW (CY360).
- The maker claims 30-50% less volume, 30% less weight and up to 40% energy saving versus traditional chillers.
- Part-load COP is computed as rated COP x (capacity % / electricity %); in the example C90 goes from 6.05 to 6.95.
Using it in design
- In pre-sizing, match the capacity step to the redundancy scheme (N+1) and carry each model's evaporator and condenser flow and pressure drop into the piping and pump calculation.
- Calculate pump power separately from the chiller input: the CY package lists chilled and condenser pumps on their own lines, and the electrical load is the sum of both.
- For structural and lifting checks, enter shipping and operating weights (for example 22400 kg for C360) into the floor-loading and crane plan.
- Evaluate IPLV against the annual load profile in the PUE calculation, and request manufacturer curves for operation outside the 12/7 °C condition.
- Do not use manufacturer claims (savings, maintenance percentages) as comparison criteria without certified data.
Who should read it
Mechanical engineers designing chilled-water plants and data-centre project teams making preliminary chiller selections.
Document contents
- Packaged Power-efficient Chiller
- Working Principle
- Rated Parameters
- Performance Curves and Model Selection Curves
- Nomenclature
- Combination with Non-electric Chiller
- Model Selection and Ordering
- Supply Scope
- Design and Construction Tips
- Dimensions and P&I Diagram
- Machine Room Construction Tips
- Control System
- Exterior Wiring Diagram
- Lifting and Leveling Tips
Publication details
- Authors
- BROAD
- Publisher
- BROAD
- Year
- 2018
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
BROAD (2018). BROAD Power Efficient Chiller Catalogue 2018, printed p.2. BROAD. https://broadusa.com/broad/wp-content/uploads/2020/04/BROAD-Power-Efficient-Chiller-Catalog-2018.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.