Data Center Power Control Solutions
ComAp
A 32-page ComAp brochure on paralleling controllers for data-centre backup generator systems: synchronised start-up of a generator bank, seamless transfer back to the mains, and parallel operation of up to 31 gen-sets under one mains controller.
On this page
Overview
The brochure presents, from a data-centre angle, the product range of ComAp, a developer of electronic control solutions for the power generation and engine drive markets. The company works with more than 400 employees, 21 offices and over 60 distributors. The document opens with three application examples: data centres, independent power production (IPP) at sites where the mains is unavailable or insufficient, and backup power systems. Feature lists follow for gen-set controllers, mains supervision controllers, operator displays and software tools.
The backup power section is the core for a data-centre designer. A backup power system is defined as a mains-independent source used when the mains fails or becomes unstable. The Start Up Synchronisation function of ComAp controllers lets a bank of gen-sets deliver power in a very short time, and when the mains returns the controllers synchronise and transfer back seamlessly. In independent production, the controllers run the number of gen-sets the current demand requires, which cuts fuel use and unnecessary running hours.
On the generator side, the InteliGen 200 and InteliGen 500 paralleling controllers offer phase-match or slip synchronisation, isochronous (via CAN) or droop load and VAr sharing, a built-in AVR interface, an internal PLC, a history of up to 350 events, and Modbus RTU/TCP and SNMP support. InteliGen NTC BaseBox and InteliSys NTC BaseBox address complex applications: controller redundancy, AMF, baseload, import/export and peak-shaving modes, and an event history of up to 1000 records (4000 on InteliSys). InteliSys is positioned for data centres, hospitals and banks.
On the mains side, InteliMains NTC BaseBox and InteliMains 210 supervise groups of up to 31 gen-sets running in parallel with the mains. Applications with several mains incomers, bus-tie breakers and load management can be built, and both reverse synchronisation of the loaded gen-set group to the mains and forward synchronisation of the mains to the group are supported. The controllers comply with VDE-AR-N 4105:2018 and VDE-AR-N 4110:2018. The brochure lists product features; it has no numerical data on synchronisation times, load acceptance or example single-line diagrams.
Key points
- Start Up Synchronisation lets a generator bank synchronise together and deliver power quickly; return to mains uses seamless synchronisation.
- InteliMains NTC BaseBox and InteliMains 210 supervise up to 31 gen-sets in parallel to mains (or in isolated parallel).
- InteliMains NTC BaseBox: 12 binary inputs, 12 binary outputs, 3 analogue inputs, 1 analogue output; supports several mains incomers and bus-tie breakers.
- Synchronisation types: phase match or slip synchro. Load and VAr sharing: isochronous (CAN) or droop, including emergency droop.
- Grid code compliance: VDE-AR-N 4105:2018 and VDE-AR-N 4110:2018; InteliGen GSC-C includes single fault tolerance.
- Event history: 350 events on InteliGen 200/500 and InteliMains 210, 1000 records on the NTC BaseBox units, 4000 records on InteliSys NTC BaseBox.
- Measurement ranges selectable at 120/277 V and 0...1 / 0...5 A; the NTC BaseBox controllers support controller redundancy.
- Communication: CAN, RS485, RS232, Ethernet, Modbus RTU/TCP, SNMP; remote monitoring through AirGate and WebSupervisor.
- InteliVision displays operate from -30 to +70 °C; InteliVision 12Touch has 1280 x 800 pixels, 1000 cd/m² and an IP65 front face.
- InteliBifuel provides bi-fuel control that substitutes up to 70% of diesel fuel with gas.
Using it in design
- In the generator paralleling switchboard specification, define start-up synchronisation and seamless retransfer to mains as functions, and measure the times during commissioning tests.
- For an N+1 generator group, fix the load-sharing method (isochronous over CAN or droop) and the emergency droop behaviour on CAN bus failure.
- In schemes with several mains incomers and bus ties, provide a supervision controller for each mains and tie breaker, and check the 31 gen-set limit per group.
- For critical facilities, write controller redundancy and single fault tolerance into the specification so the control system is not a single point of failure.
- Connect gen-set controllers to the BMS/DCIM over Modbus TCP or SNMP, and compare event history depth with fault analysis requirements.
- Where parallel operation with the grid is planned, confirm local grid code conditions with the utility; VDE compliance covers the German rules.
Who should read it
Electrical engineers designing data-centre backup power systems, authors of generator paralleling switchboard specifications, and commissioning teams.
Document contents
- Smart Control Solutions
- Application Examples: Data centers, Independent Power Production, Backup Power System
- InteliGen 200 and InteliGen 500: Parallel Gen-set Controllers
- InteliGen GSC-C, InteliGen NTC BaseBox, InteliSys NTC BaseBox
- InteliSys NTC Hybrid: Renewable/diesel hybrid system controller
- InteliMains NTC BaseBox and InteliMains 210: Mains supervision controllers
- InteliBifuel: Bi-fuel control system
- InteliVision 5 and InteliVision 12Touch display units
Publication details
- Authors
- ComAp
- Publisher
- ComAp
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Official public manufacturer source inspected. No redistribution permission established. Metadata and original brief summaries only; local files are research evidence, not a redistribution package.
Citation
ComAp Data Center Power Control Solutions. ComAp. https://uk.comap-control.com/getmedia/f1a424af-b358-4c70-9508-17c41a1c1492/DataCentre_brochure_2022.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.