DESMI Data Center Application: Pumps for Cooling, Water Intake, Excess Heat and Backup Power

Original title Data Center: industry and utility application

DESMI

DESMI's data centre application page: NSL (2,400 m³/h, 195 m), DSL (6,200 m³/h) and ESLH (200 m³/h) centrifugal pumps and the ROTAN GP gear pump for cooling, water intake, heat reuse and fuel systems.

On this page

Overview

The page says rising AI, machine learning and similar workloads are pushing data centre infrastructure towards higher standards of reliability, resiliency and energy efficiency, and presents DESMI's pump portfolio in that context. Scope covers immersion cooling, direct liquid cooling, facility water systems, water intake, excess heat reuse and backup power fuel systems.

In the cooling section the centrifugal pump range is said to support the major approaches, air-cooled infrastructure, direct liquid cooling and immersion cooling, with low NPSH values, high hydraulic efficiency and magnetic coupling options, helping PUE and CUE scores. The water intake section stresses fluctuating temperature, flow resistance, and corrosive or debris-laden water when drawing from lakes or fjords, requiring wear-resistant materials and flexible, efficient control.

Product summaries: NSL vertical in-line centrifugal pump (flow up to 2,400 m³/h, head up to 195 m), DSL double-suction in-line centrifugal (up to 6,200 m³/h at 50 Hz), ESLH end-suction centrifugal with horizontal inlet (DN 25-100, up to 200 m³/h) and the simple, compact ROTAN GP internal gear pump for non-abrasive liquids. The heat section describes passing heat to district heating and cites Fjernvarme Fyn. For fuel pumps it highlights high reliability, consistent fuel delivery for fast generator start, 24/7 standby durability and multi-pump configuration. The page is product promotion and gives no design conditions or curves.

Key points

  1. NSL: vertical in-line centrifugal pump, flow up to 2,400 m³/h and head up to 195 m.
  2. DSL: in-line double-suction centrifugal, up to 6,200 m³/h (27,300 US gpm) at 50 Hz.
  3. ESLH: end-suction centrifugal with horizontal inlet, DN 25-100, up to 200 m³/h (880 US gpm).
  4. ROTAN GP: internal gear pump for non-abrasive liquids.
  5. Centrifugal pumps offer low NPSH, high hydraulic efficiency and magnetic coupling options, supporting air, direct liquid and immersion cooling.
  6. Intake from natural water needs wear-resistant materials and efficient control for fluctuating temperature, flow resistance and debris.
  7. Excess heat is passed to district heating; the Fjernvarme Fyn case is cited.
  8. Fuel pumps: high reliability, consistent fuel delivery, 24/7 standby systems, redundancy and emergency-operation testing, compatibility with leading diesel generator brands.

Using it in design

  • Set pump flow and head from your system curve; the 2,400, 6,200 and 200 m³/h figures are upper limits, not selection points.
  • Evaluate low NPSH and high hydraulic efficiency over 8,760 operating hours a year and the PUE effect.
  • For direct liquid or immersion loops, decide from fluid compatibility whether a magnetic-coupled (sealless) pump is needed.
  • For natural water intake, write material, strainer and debris management and variable-flow control into the design.
  • Design N+1 or multi-pump fuel configurations together with generator fuel line redundancy.

Who should read it

Mechanical designers selecting pumps for cooling water, heat reuse and generator fuel lines.

Document contents

  1. Data center pump solutions
  2. How pumps support cooling
  3. Stable water intake
  4. Pumps for data centers
  5. Turning waste into warmth
  6. Why data centers choose DESMI fuel pumps

Publication details

Authors
DESMI
Publisher
DESMI
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

DESMI Data Center: industry and utility application. DESMI. https://www.desmi.com/segments/industry-utility/applications/energy-applications/data-center/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.