Eaton Universal-Input Rack PDU G4

Eaton

Eaton's G4 universal-input rack PDU brochure (BR155055EN): single- or three-phase chassis, with separately selected input cable and C39 outlets setting the usable input rating.

On this page

Overview

Eaton's brochure BR155055EN is a product-selection reference showing how chassis and input cables are paired in the universal-input rack PDU G4 family. Universal-input chassis support single-phase or three-phase configurations; because the input cable is selected separately from the chassis, regional ratings are set by the cable choice.

The brochure also explains the connection types of the C39 outlets: C39 outlets accept C13 and C19 connections. The outlet quantity in the document is the number of physical sockets; it is not the sum of C13 and C19 compatibilities.

Key points

  1. Universal-input chassis support single-phase or three-phase configurations.
  2. The selected input cable sets the usable input rating.
  3. Input cables are selected separately from the chassis; regional ratings depend on the cable.
  4. C39 outlets accept C13 and C19 connection types.
  5. Outlet quantity is the number of physical sockets, not the sum of the two connector compatibilities.

Using it in design

  • Specify the rack PDU as a chassis and input-cable pair and read the rating from the cable.
  • Choose single-phase or three-phase input according to the rack supply design.
  • Count outlets as physical C39 sockets and plan the C13/C19 load mix accordingly.

Who should read it

Electrical designers and IT infrastructure teams selecting rack-level power distribution.

Publication details

Authors
Eaton
Publisher
Eaton
Year
Year not stated
Document number
BR155055EN
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Eaton Eaton Universal-Input Rack PDU G4. Eaton. BR155055EN. https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/power-distribution-for-it-equipment/eaton-rack-pdu-g4/resources/eaton-universal-input-rack-pdu-g4-brochure-br155055en.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.