Technical guideFree to read2026

MATSN automatic transfer switch catalogue

Eaton

Eaton's 2026 catalogue (CA008019EN) distinguishes CCC and CB ratings and supplies order references for separate-controller three-position switches.

On this page

Overview

The catalogue covers the MATSN series of automatic transfer switches. For separate-controller three-position switches it distinguishes the CCC and CB ratings and gives order references for each configuration.

The rating distinction determines which definition the short-circuit withstand and protection conditions are tied to, so CCC and CB values must not be mixed in product selection.

Key points

  1. Product: MATSN automatic transfer switch, separate-controller three-position switch.
  2. CCC and CB ratings are given separately.
  3. Order references are supplied for separate-controller three-position switches.
  4. Document number CA008019EN, published 2026.

Using it in design

  • When selecting an ATS, assess the CCC and CB ratings separately and state which rating the specification requires.
  • Record the order reference for switch and controller together, because the controller is separate.
  • Define the three-position switch structure in the maintenance and lock-out procedure.
  • Compare the selected rating with the short-circuit conditions at the installation point.

Who should read it

Electrical designers selecting Eaton ATS and engineers writing specifications.

Publication details

Authors
Eaton
Publisher
Eaton
Year
2026
Document number
CA008019EN
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Eaton (2026). MATSN automatic transfer switch catalogue. Eaton. CA008019EN. https://www.eaton.com/content/dam/eaton/products/low-voltage-power-distribution-controls-systems/automatic-transfer-switches/matsn/catalogs/eaton-matsn-automatic-transfer-switch-catalog-ca008019en-us.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.