Ebara EVMS 50 Hz Technical Data Book, Rev G EPA September 2025
Ebara
The Ebara EVMS vertical multistage pump data book gives 50 Hz performance tables across 10 sizes from 1 to 90 m³/h nominal flow, 16-35 bar maximum pressure and -30 to +140 °C liquid temperature.
On this page
Overview
Ebara's EVMS series are non-self-priming, in-line vertical multistage centrifugal pumps. The data book (Rev G, September 2025) covers ten sizes at nominal flows of 1, 3, 5, 10, 15, 20, 32, 45, 64 and 90 m³/h. It comprises typical applications, performance range, product features, shaft seal, type key and nameplate, selection chart, per-model performance tables, packing and motor data.
The pumps can run at maximum working pressures of 16, 25, 30 or 35 bar, with a liquid temperature range of -30 to +140 °C (the manufacturer asks to be contacted for -30 to -15 °C and 120-140 °C). Material options are AISI 304, AISI 316L and cast iron. Pumps above 0.75 kW come with IE3 motors, and motors of 1.5 kW and above have PTC sensors pre-installed. Shaft seal options are tabulated for 16 and 25 bar classes in EPDM or FPM with SiC and carbon faces.
For each size the data book gives tables by stage count for EVMS(L), EVMSG and related versions. Rows carry model name, motor power, maximum pressure and dimensions and weight together (for example the EVMS(L)1 2 model has a 0.37 kW motor at 1.6 MPa). Flow and head are paired in the same table; these are not a duty point selected for a particular plant. Motor rated power is separate from electrical consumption measured at the selected flow.
Key points
- Pump type: in-line, non-self-priming, vertical multistage centrifugal.
- Nominal flow sizes: 1, 3, 5, 10, 15, 20, 32, 45, 64, 90 m³/h.
- Maximum working pressure 16, 25, 30 or 35 bar.
- Liquid temperature range -30 to +140 °C (contact the manufacturer at the extremes).
- Materials: AISI 304, AISI 316L, cast iron.
- IE3 motors above 0.75 kW; PTC sensor at 1.5 kW and above.
- Shaft seal examples: 16 bar -30/+120 °C EPDM; 25 bar -30/+140 °C balanced seal.
- The data book pairs flow and head in one table for 53 model rows.
- Motor rated power is separate from measured consumption; material variants are not duplicated into separate rows.
Using it in design
- Read flow and head from the system-curve intersection when selecting pumps; do not use paired table values as a design point.
- In chilled water and glycol circuits, choose shaft seal and elastomer by liquid temperature and pressure class.
- Evaluate motor power with measured consumption and IE3 efficiency rather than as a rated value alone.
- Plan parallel and standby pump arrangements by size.
- Choose material (AISI 304, 316L, cast iron) by liquid quality.
Who should read it
Mechanical designers and procurement engineers selecting chilled water and auxiliary circuit pumps.
Document contents
- Specifications
- Product features
- Product specifications
- Shaft seal
- Type key and nameplate
- Performance range and selection chart
- Per-model curves and tables
- Packing
- Motor data
Publication details
- Authors
- Ebara
- Publisher
- Ebara
- Year
- 2025
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Ebara (2025). Ebara EVMS 50 Hz Technical Data Book, Rev G EPA September 2025. Ebara. https://ebara.com.au/wp-content/uploads/2024/10/Data-Book_EVMS.1-90_50Hz_EN_rev.G-EPA_Sept-2025_revised-1.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.