Ebara Shinwa SNC-U Cooling Tower
Ebara Shinwa
Ebara Shinwa SNC-U is a cross-flow square-type cooling tower series with built-in piping; the maker states an average 20% reduction in dry and wet weight and installation space against older models.
On this page
Overview
The brochure (document no. ASEC-001) presents the SNC-U as a cross-flow square tower designed to install in a small space. Highlighted themes are energy saving, space saving, compact and lightweight build, and high efficiency and performance. A high-efficiency fill combined with the eliminator, a cone-shaped fan casing and the super-low-noise AVS fan are used together; the maker says installation space, volume and dry and wet weight fall by 20% on average against older models.
U-series towers are supplied with built-in piping as standard, which saves cost and space in installation work. Options are split into internal (ASSY) and external piping (ASSD). The new SRS wedge-belt speed reducer is compact and easy to maintain; the FRP lower basin is sloped for easy cleaning. On request the tower is delivered semi-assembled at site, which shortens installation time.
The brochure's second part covers selection, standard specifications and noise level. Tables give, per model for two water temperature and wet-bulb conditions, water flow (L/min), dimensions, connection sizes, dry and operating weight, fan motor power and quantity (3-phase 400 V 50 Hz; 380 and 415 V on request) and dB(A) levels at louver side and casing panel side. Models run from the SNC-U 280 to the 1400 series. Fan motor power is not measured electrical consumption.
Key points
- Cross-flow square-type tower designed for small spaces.
- Average 20% less dry and wet weight and installation space (against older models).
- Built-in piping is standard; ASSY and ASSD options have separate shipping weights.
- Cone-shaped fan casing, fill-and-eliminator combination and super-low-noise AVS fan.
- SRS wedge-belt speed reducer; sloped FRP lower basin.
- Fan motor 3-phase 400 V 50 Hz; 380 and 415 V on request.
- Noise level given separately for louver side and casing-panel side in dB(A).
Using it in design
- For a tight roof or courtyard, verify dimensions and air-inlet clearances from the table.
- Take shipping weights of the internal (ASSY) and external (ASSD) piping options separately into roof load and crane planning.
- On a noise-limited site compare louver-side and panel-side dB(A) with the neighbouring facade.
- Read fan motor power together with the quantity for the electrical load; verify the voltage against the site supply.
Who should read it
Mechanical designers selecting cooling towers for tight spaces and engineers planning site layout.
Document contents
- Features
- Built-in piping arrangements
- Easier maintenance
- Reduced installation time
- Selection, standard specifications and noise level
Publication details
- Authors
- Ebara Shinwa
- Publisher
- Ebara Shinwa
- Year
- Year not stated
- Document number
- ASEC-001
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Ebara Shinwa Ebara Shinwa SNC-U Cooling Tower. Ebara Shinwa. ASEC-001. https://www.ebaraindonesia.com/wp-content/uploads/2022/10/Brochure_Model_SNC-U.pdf