Technical guideFree to readYear not stated

MIT Cooling Tower Product Catalogue

Original title MIT Soğutma Kulesi Ürün Kataloğu

Ekin Endüstriyel (MIT)

Ekin Endüstriyel's MIT-SK cooling tower catalogue gives external dimensions, fan motors, weights and water flow ranges for models MIT-SK 13 to 37.

On this page

Overview

The Ekin Endüstriyel (MIT) catalogue tabulates external dimensions, fan motor power, weight and water flow ranges for MIT-SK 13-37 models. The tables give flow ranges; no single thermal duty or rating temperature is published.

Cooling kW for the models therefore cannot be derived from the table; capacity needs the water inlet and outlet temperature and wet-bulb condition from the manufacturer. External dimension, motor and weight data can be used for layout, roof load and electrical calculation.

Key points

  1. Models MIT-SK 13 to 37 are covered.
  2. External dimensions, fan motors and weights are tabulated.
  3. Water flow ranges are given.
  4. No rating temperature or single thermal duty is published; cooling kW cannot be derived.

Using it in design

  • Compare the flow range with the project flow and obtain capacity confirmation from the manufacturer for water temperatures and wet-bulb condition.
  • Carry external dimension and weight into layout and roof load.
  • Use fan motor power as input to the electrical load and the variable-speed drive decision.
  • Do not derive heat rejection kW from the flow range; calculate the heat load separately from flow and temperature difference.

Who should read it

Mechanical designers selecting cooling towers and purchasing engineers.

Publication details

Authors
Ekin Endüstriyel (MIT)
Publisher
Ekin Endüstriyel (MIT)
Year
Year not stated
Document language
Turkish
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Ekin Endüstriyel (MIT) MIT Soğutma Kulesi Ürün Kataloğu. Ekin Endüstriyel (MIT). https://www.ekinendustriyel.com/uploads/files/sogutma-kulesi-urun-katalogu-9662.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.