Yangın Var!: Binalarda Elektrik Tesisatı, Yangın Güvenliği ve Standartlar (Fire!: Electrical Installations, Fire Safety and Standards in Buildings)
Original title Yangın Var!: Binalarda Elektrik Tesisatı, Yangın Güvenliği ve Standartlar
TMMOB Elektrik Mühendisleri Odası · Sabri Günaydın
A May 2013 EMO article in Elektrik Mühendisliği showing that 20.66 percent of Istanbul's 25,469 fires in 2012 were electrical, and listing the IEC 60364, HD 60364 and EN standards that govern design, verification and maintenance.
On this page
Overview
Sabri Günaydın's three-page article attributes electrical-installation fires to non-compliance with standards and to outdated regulations. It notes that the draft Electrical Internal Installations Regulation that EMO prepared and sent to the Ministry of Energy and Natural Resources in 2005 had still not been issued eight years later, and the text reads as a call for an update.
The evidence is Istanbul fire brigade statistics. Of 25,469 fires in 2012, 12,399 were caused by cigarettes and 5,012 by electrical contact; transformer fires numbered 251. The electrical share is given as 20.66 percent in Istanbul and about 20 percent nationally. It also reports 233 deaths in 30,371 incidents in Istanbul in 2010.
The core is two lists and one principle. The first list names the standards tied to installation fire safety: IEC 60364, HD 60364, EN 54, EN 1366-3 (service penetration seals), EN 62305 (lightning protection), EN 50174 and EN 50310, among others. The second lists causes: wrong cable sizing, skipped verification and periodic testing, untested firestopping in fire zones, ignored harmonics and counterfeit products. The principle is to demand type-test certificates and post-production routine-test certificates at material approval.
The article dates from 2013, so the standard editions and Turkish regulations it lists reflect that time and the current legal position must be checked separately. It is not specific to data centres, but it supports lifecycle coordination between design, verification, operation and maintenance.
Key points
- Istanbul had 25,469 fires in 2012; the top cause was cigarettes (12,399 fires) and the second electrical contact (5,012 fires).
- Electrical installations caused 20.66 percent of fires in Istanbul and about 20 percent in Turkey overall.
- In 2010 Istanbul Fire Brigade attended 30,371 incidents; 233 people died and 630 were injured, 35 of them firefighters.
- EMO's draft regulation sent to the Ministry on 21 May 2005 remained unpublished eight years later.
- Core standards are the IEC 60364, HD 384 and HD 60364 series; related fire standards include IEC 60331, EN 54, EN 1366-3, EN 62305 and EN 61439.
- Causes include skipped HD 60364-6 verification and periodic tests, wrong cable and panel sizing, and ignored harmonics.
- Type-test certificates for flame retardance (FR) should be required for cables, busbars and cable trunking, and routine-test certificates sent to the employer.
Using it in design
- Add flame-retardant type-test certificates and delivery of routine-test certificates to the electrical specification for cables, busbars and trunking.
- Collect EN 1366-3 tested firestop systems and their documents in the commissioning file for fire-compartment penetrations.
- Write HD 60364-6 style initial verification tests and an in-service periodic inspection schedule into the commissioning plan.
- Check harmonic effects of non-linear data centre loads in cable and panel sizing.
- Verify standard editions and current Turkish regulations independently rather than relying on this 2013 article.
Who should read it
Electrical design and installation engineers, commissioning and inspection teams, and technical managers writing specifications.
Document contents
- Introduction: outdated standards and regulations
- Istanbul fire statistics
- Standards and directives related to fire safety
- Causes of fires from electrical installations
- Type tests and routine tests
- The regulation fire
Publication details
- Authors
- Sabri Günaydın
- Publisher
- TMMOB Elektrik Mühendisleri Odası
- Year
- 2013
- Document number
- Elektrik Mühendisliği, Sayı 447, Mayıs 2013
- Document language
- Turkish
- Source type
- Industry body
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Official publisher or university publicly accessible text; no open redistribution licence established.
Citation
Sabri Günaydın (2013). Yangın Var!: Binalarda Elektrik Tesisatı, Yangın Güvenliği ve Standartlar. TMMOB Elektrik Mühendisleri Odası. Elektrik Mühendisliği, Sayı 447, Mayıs 2013. https://emo.org.tr/emoyayin/makale/915/yangin-var
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.