ENEX Technologies Flat Dry Cooler DHN/DCH

ENEX Technologies

ENEX Technologies' DHN/DCH flat dry cooler guide gives representative model tables; the SC15 duty is 40/35°C water and 25°C entering air.

On this page

Overview

The guide combines representative model tables for ENEX Technologies' DHN and DCH flat dry coolers, the SC15 capacity conditions and the limit of final circuit selection. The SC15 duty is defined as 40/35°C water and 25°C entering air. The tables carry representative model codes, fan power and mass.

For final connection and circuit selection the guide points to the manufacturer's selection software. The DHN fan diameter is given differently in the text and in the table, so the exact diameter needs manufacturer confirmation.

Key points

  1. Subject: ENEX DHN and DCH flat dry coolers.
  2. SC15 capacity duty: water 40/35°C, entering air 25°C.
  3. The tables give representative model codes, fan power and mass.
  4. Final connection and circuit selection uses the manufacturer's software.
  5. DHN fan diameter differs between text and table; the exact value is confirmed with the manufacturer.

Using it in design

  • Do not use capacity without correcting from 25°C entering air to your own design outdoor temperature; capacity falls in a data centre environment.
  • Use the fan power and mass columns for electrical load and structural support pre-calculations.
  • Settle fan diameter and connection/circuit selection from the manufacturer's selection software output.

Who should read it

Mechanical designers selecting flat-type dry coolers.

Publication details

Authors
ENEX Technologies
Publisher
ENEX Technologies
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

ENEX Technologies ENEX Technologies Flat Dry Cooler DHN/DCH. ENEX Technologies. https://www.enextechnologies.com/wp-content/uploads/2024/08/Flat-Dry-cooler-DHN-DCH_ENG.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.