Turkey National Electricity Grid Emission Factor Information Form (2023)

Original title Türkiye Ulusal Elektrik Şebekesi Emisyon Faktörü Bilgi Formu: 2023

Enerji ve Tabii Kaynaklar Bakanlığı / EVÇED

The Turkish Ministry of Energy and Natural Resources form for 2023 gives grid emission factors by the UNFCCC CDM Tool 07 method: operating margin 0.7134 and build margin 0.3567 tCO2/MWh.

On this page

Overview

The form announces the emission factor of the national electricity grid as an operating margin (OM), a build margin (BM) and a combined margin (CM). Values for the 2023 calculation period were published on 26.12.2025. The method is the UNFCCC Clean Development Mechanism Tool 07, version 7.0. The document is numbered ETKB-EVCED-FRM-039 Rev.03 and its purpose is to inform stakeholders of the annually calculated grid emission factor.

The operating margin emission factor is 0.7134 and the build margin emission factor is 0.3567 tCO2/MWh. From these, two combined margin factors are derived by source type: 0.6242 tCO2/MWh for solar and wind plants and 0.5350 tCO2/MWh for other renewable plants. The combined margin values result from weighting the operating and build margins and give different results for the two source groups.

The data set includes TEIAS generation, consumption and loss statistics, electricity generation emissions (1.A.1.a.i) from the national greenhouse gas inventory, commissioning dates, fuel types, installed capacities and generation of plants from TEIAS load dispatch, ownership of voluntary carbon certificates (Gold Standard, VCS, GCC), and plant efficiencies from CDM Tool 09. Because the data set draws on both national statistics and international programme registries, the calculation depends on data from several bodies.

The intended use is narrow: the combined margin factors are for calculating greenhouse gas reductions achieved through renewable generation. Generation and consumption-point factors describing average emissions on the demand side are published in a separate form, and the two documents should not be used interchangeably. Since a new form is published each year, users must select the correct year and revision number.

Key points

  1. Operating margin (OM) emission factor, 2023: 0.7134 tCO2/MWh.
  2. Build margin (BM) emission factor, 2023: 0.3567 tCO2/MWh.
  3. Combined margin factor for solar and wind: 0.6242 tCO2/MWh.
  4. Combined margin factor for other renewables: 0.5350 tCO2/MWh.
  5. Method: UNFCCC CDM Tool 07 version 7.0; Tool 09 version 3.0 for plant efficiencies.
  6. Calculation published 26.12.2025; document no. ETKB-EVCED-FRM-039 Rev.03.

Using it in design

  • When calculating the emission reduction from the data centre's own renewable generation (for example rooftop PV), use the combined margin value matching the source type.
  • For the average carbon footprint of electricity drawn from the grid, use the separately published generation and consumption-point factors, not this form; margin factors belong to reduction-credit logic.
  • State in the design report which factor (OM, BM, CM) and which year was used in any carbon-reduction claim.
  • When assessing a PPA or renewable certificate strategy, include the difference between the solar-wind (0.6242) and other-renewable (0.5350) factors in the sensitivity analysis.

Who should read it

Engineers preparing carbon-reduction projects, data-centre planners assessing renewable and PPA strategy, and sustainability reporting teams.

Document contents

  1. Purpose
  2. Scope
  3. Calculation methodology
  4. Data set
  5. Grid emission factor (OM, BM)
  6. Combined margin emission factors

Publication details

Authors
Enerji ve Tabii Kaynaklar Bakanlığı / EVÇED
Publisher
Enerji ve Tabii Kaynaklar Bakanlığı / EVÇED
Year
2025
Document number
ETKB-EVÇED-FRM-039 Rev.03; hesaplama 2023, yayım 26.12.2025
Document language
Turkish
Source type
Government / public
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Açık erişim yeniden dağıtım izni anlamına gelmez; açık yeniden dağıtım lisansı saptanmadı. Kütüphanede tam metin yayımlanmaz.

Citation

Enerji ve Tabii Kaynaklar Bakanlığı / EVÇED (2025). Türkiye Ulusal Elektrik Şebekesi Emisyon Faktörü Bilgi Formu: 2023. Enerji ve Tabii Kaynaklar Bakanlığı / EVÇED. ETKB-EVÇED-FRM-039 Rev.03; hesaplama 2023, yayım 26.12.2025. https://enerji.gov.tr/Media/Dizin/EVCED/tr/%C3%87evreVe%C4%B0klim/%C4%B0klimDe%C4%9Fi%C5%9Fikli%C4%9Fi/TUESEmisyonFktr/Belgeler/Sebeke_EF_Bilgi_Formu_2023.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.