Energy Efficiency in Air-Conditioning and Refrigeration Systems

Original title İklimlendirme ve Soğutma Sistemlerinde Enerji Verimliliği

Friterm · Kadir İsa, Ayhan Onat

Friterm Technical Book Series No. 02 by Dr. Kadir İsa and Dr. Ayhan Onat (2nd edition, 2017, about 460 pages): a Turkish reference on efficiency of chillers, dry coolers, cooling towers and pumps.

On this page

Overview

The book is the second technical title of Friterm Akademi; the first edition dates from September 2012 and the expanded second edition from August 2017. The preface states an average saving potential of 30% in Turkey through energy-efficiency measures. It treats all main components of cooling and air-conditioning systems from the energy-efficiency angle.

The refrigeration part covers chillers (water- and air-cooled), compressor types (reciprocating, centrifugal, screw, scroll, rotary), evaporators, condensers, dry coolers, open and closed-circuit cooling towers, pumps, controls, absorption chillers and ice storage. The air-conditioning part addresses air handling units, filters, heat recovery, fans and chilled beams.

The parts most relevant to data-centre design are the free-cooling sections. The book presents chillers with integrated free-cooling coils as an alternative for server rooms and data centres that need cooling 24 hours a day, and cites a UK case where 62% of annual cooling demand is met by free cooling. In a water-side economiser, cooling-tower water is separated from the chilled-water loop by a plate exchanger.

The last chapters show energy-audit steps and the payback, net present value and internal rate of return methods through a sample industrial and building audit. The book is a general HVAC source, not specific to data centres, and contains no limits based on ASHRAE or Uptime classification.

Key points

  1. The preface states a 30% average saving potential in Turkey through efficiency work.
  2. The book has six main parts; the refrigeration part (Part 4) includes sections on dry coolers and cooling towers.
  3. In the UK example 62% of annual cooling demand is met by free cooling and only 38% by mechanical cooling.
  4. Chillers with integrated free-cooling coils are presented as an option for data centres needing 24-hour cooling.
  5. In a water-side economiser a plate heat exchanger isolates cooling-tower water from the closed chilled-water loop.
  6. Plate exchangers can reach a temperature approach as low as 1 °C; shell-and-tube units need 5 °C or more.
  7. For an 870 kW four-fan dry cooler, lowering fan speed when ambient falls from 33 °C to 20 °C saves 0.75 kW per fan, close to 40%.
  8. Pumps (the Ecodesign requirements regulation) and control systems each have their own efficiency sections.

Using it in design

  • Stage dry-cooler fan speed against ambient temperature; since fan power falls steeply with speed, base the annual energy estimate on the part-load fan curve.
  • In designs with cooling towers, build the water-side economiser with a plate exchanger and plan a water-treatment programme for the chilled-water loop.
  • Compare an integrated free-cooling chiller with a separate economiser layout on annual free-cooling hours.
  • Carry the exchanger approach temperature (plate 1 °C, shell-and-tube 5 °C) into the calculation of the free-cooling changeover temperature.
  • Remember that condenser fouling raises condensing temperature, and add water treatment and cleaning to operating requirements.

Who should read it

Mechanical engineers designing cooling plant, energy managers and project teams choosing data-centre cooling solutions.

Document contents

  1. Part 3: Air-Conditioning Systems
  2. Part 4: Energy Efficiency in Refrigeration Systems (chillers, compressors, evaporators, condensers, dry coolers, cooling towers, pumps, controls, absorption chillers, ice storage)
  3. Part 5: Efficiency Methods in Air-Conditioning Systems (air handling units, filters, insulation, heat recovery, fans, chilled beams)
  4. Part 6: Sample Energy Audits

Publication details

Authors
Kadir İsa; Ayhan Onat
Publisher
Friterm
Year
2017
Document number
Teknik Kitaplar Dizisi No. 02; 2. baskı; ISBN 978-975-6263-22-8
Document language
Turkish
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Üreticinin herkese açık kaynağı okundu. Açık erişim yeniden dağıtım izni değildir; tam metin kütüphaneye alınmaz. Künye PDF s. 6: Ağustos 2017, genişletilmiş 2. baskı. Aynı sayfa yazar/Friterm izni olmadan çoğaltmayı yasaklar. Yalnızca yazarların seçilen Türkçe bölümlerinden kısa özgün açıklama; ASHRAE belgesinden içerik alınmadı.

Citation

Kadir İsa; Ayhan Onat (2017). İklimlendirme ve Soğutma Sistemlerinde Enerji Verimliliği. Friterm. Teknik Kitaplar Dizisi No. 02; 2. baskı; ISBN 978-975-6263-22-8. https://www.friterm.com/storage/documents/01JZ7MM2SPV25972APSQGETMB1.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.