Precision Fan Wall Array Air Conditioner for Computer Room (Hicon HFQ/HFQSD)

Original title Precision Fan Wall Array Air Conditioner for Computer Room

Hicon

The Hicon HFQ and HFQSD fan wall precision air conditioner table compares DX and chilled water models with single and double coil options; the power row covers fans only.

On this page

Overview

Hicon's product page presents fan wall array precision air conditioners for computer rooms as DX and chilled water models. The manufacturer's table compares these models and the single and double coil options.

In the DX model columns, single and double coil options are given at the same capacity with different depth and weight. The power row in the table covers fans only, so total unit electrical input must be obtained separately from the manufacturer.

Key points

  1. DX and chilled water fan wall models are compared in the table.
  2. Single and double coil options are offered at the same capacity.
  3. Single and double coil options differ in depth and weight.
  4. The power row covers fans only.

Using it in design

  • Because capacity is equal, choose the coil option by room depth and floor loading.
  • Do not use fan power as total electrical input; obtain compressor and control power from the manufacturer.
  • Separate the DX and chilled water models by the plant's cooling source.

Who should read it

Data-centre mechanical designers selecting fan wall precision air conditioners.

Publication details

Authors
Hicon
Publisher
Hicon
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Hicon Precision Fan Wall Array Air Conditioner for Computer Room. Hicon. https://hiconglobal.com/precision-air-conditioner/precision-fan-wall-array-air-conditioner-for.html

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.