Building Next Generation Data Center Facility in ASEAN (ACE and Huawei White Paper)
Original title Building Next Generation Data Center Facility in ASEAN
ASEAN Centre for Energy / Huawei · ASEAN Centre for Energy, Huawei
The white paper released by the ASEAN Centre for Energy and Huawei on 17 May 2024 describes the next-generation data centre as Reliable, Simplified, Sustainable and Smart and recommends discounted tariffs or tax breaks for clean energy.
On this page
Overview
The white paper Building Next Generation Data Center Facility in ASEAN, co-developed by the ASEAN Centre for Energy (ACE) and Huawei, was released on 17 May 2024 at the Global Data Center Facility Summit 2024 in Singapore. Its aim is to accelerate the green and low-carbon transformation of the data-centre industry in ASEAN. The announcement says that because of tropical climates, ASEAN data centres have high cooling requirements, high energy consumption and PUE values far above the global average.
The white paper lists four characteristics of a next-generation data centre: reliable (modular design, AI preventive maintenance, lithium-ion and lithium iron phosphate batteries), simplified (hardware convergence; for a 1,000-rack data centre, prefabricated and modular construction cuts delivery from 18-24 months to 9 months and time to market by 50%), sustainable (a high-temperature chilled-water fan-wall solution that raises inlet water temperature to cut PUE and carbon) and smart (facility automation with 3D visualisation and dashboards). As a policy recommendation, it proposes discounted electricity rates or tax breaks for operators using clean energy as their main source.
Key points
- The white paper was released on 17 May 2024 in Singapore; co-developers are the ASEAN Centre for Energy and Huawei.
- Four characteristics of the next-generation data centre: reliable, simplified, sustainable, smart.
- For a 1,000-rack data centre, prefabricated and modular construction cuts delivery from 18-24 months to 9 months and time to market by 50%.
- Lithium-ion batteries offer longer life, higher energy density and a smaller footprint than lead-acid; lithium iron phosphate is preferred as more reliable and less prone to fire in thermal runaway.
- A high-temperature chilled-water fan-wall solution raises inlet water temperature to reduce PUE and carbon.
- Policy recommendation: discounted electricity rates or tax breaks for operators using clean energy.
Using it in design
- For tropical-climate facilities, evaluate a high-temperature chilled-water fan-wall solution as a way to cut PUE by raising water supply temperature.
- For large builds, include the effect of prefabricated and modular construction on delivery time (18-24 months to 9 months, vendor statement) in schedule analysis.
- When selecting backup battery technology, compare life, energy density, footprint and thermal runaway behaviour.
- Support figures in a document co-developed with a vendor with independent data and site measurement.
Who should read it
Engineers and policy makers designing data-centre facilities in ASEAN and other tropical climates.
Publication details
- Authors
- ASEAN Centre for Energy; Huawei
- Publisher
- ASEAN Centre for Energy / Huawei
- Year
- 2024
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Publisher landing page opened with TinyFish on 2026-11-16. No explicit open licence or commercial redistribution grant was displayed in the retrieved page; retained as metadata and original summary only. Free access or a download button is not permission to redistribute. Official publisher announcement dated 17 May 2024 and summit download landing page opened. Summary is limited to announcement; no full paper retained. License evidence: https://digitalpower.huawei.com/eg/news/data-center-facility/2420
Citation
ASEAN Centre for Energy; Huawei (2024). Building Next Generation Data Center Facility in ASEAN. ASEAN Centre for Energy / Huawei. https://digitalpower.huawei.com/eg/news/data-center-facility/2420
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.