IMI Hydronic: HVAC Solutions for Data Centres, 2024
Original title HVAC Solutions for Data Centres
IMI Hydronic Engineering
IMI Hydronic's 40-page 2024 brochure describes balancing and control valves, pressure maintenance, and air and dirt separation for data center hydronic circuits under five headings: precision cooling, efficiency, reliability, security and design complexity.
On this page
Overview
The brochure presents the products and approach of IMI Hydronic, specialist in balancing, pressurisation and water quality, for data center applications. It is organized around five data center HVAC demands: precision cooling, high energy efficiency, no margin for error, safety and data protection, and design complexity. It closes with reference cases and HVAC schematic examples by class, starting from Uptime Institute Tier I.
The precision cooling and efficiency sections cover STAD, STAF and TA-BVS balancing valves, STAP and TA-PILOT-R differential pressure controllers, the TA-Modulator pressure-independent control valve (PIBCV) and the TA-Slider digital actuator. The TA-Smart valve offers four control modes (flow, power, position, differential pressure), measures flow, ΔT, power and energy with ultrasonic flow and pair-calibrated Pt1000 sensors, and includes a ΔT limitation function against low ΔT syndrome.
The reliability section covers pressure maintenance (Compresso, Transfero, BrainCube Connect control unit), butyl-bag expansion vessels, air and dirt separators (Zeparo cyclonic dirt separator, Ferro Cleaner magnetic separator) and fail-safe actuators for power loss. The security section covers disabling cloud connection and access control. It is a product-focused manufacturer brochure; numeric efficiency claims are the manufacturer's.
Key points
- Five demands: precision cooling, high energy efficiency, no margin for error, safety and data protection, design complexity.
- TA-Smart (DN15 to DN125): flow, power, position and differential pressure control modes; stated to control flow as low as 0.5% of nominal at up to 400 kPa differential pressure.
- Measurement accuracy: for water 2% at 100% of qnom and 2.4% at 5% (MID Class 2, EN 1434); for water-glycol (up to 57%) 3% and 4% (MID Class 3).
- Pt1000 EN 60751 Class AA temperature sensors are pair-calibrated; TA-Smart is stated to be up to 80% smaller than competitors.
- The TA-Slider actuator offers 10x more setting parameters and up to 50% shorter commissioning than conventional actuators (manufacturer claim).
- Butyl-bag expansion vessels claim 5 to 10 times lower air diffusion than other membrane materials; BrainCube Connect links to BMS via Modbus RS485 and Ethernet.
- Master-Slave operation coordinates pressure maintenance across sub-plants several kilometres apart over Ethernet-Multicast.
- An example where a valve stayed closed after power loss, blocked minimum flow, froze the pipe and cost EUR 242k in repairs shows why a fail-safe actuator is needed.
Using it in design
- On chilled water circuits, consider a pressure-independent control valve with ΔT limitation, or a flow-measuring valve, on each tower or CRAH branch to prevent low ΔT syndrome.
- Check valve authority and the low-flow range for accurate part-load control; many systems run at about 20% of nominal flow for most operating hours.
- Design pressure maintenance as redundant and monitorable; position air and dirt separators at the pump suction and main return.
- Specify actuator fail-safe position and minimum flow position against freezing and flow loss on power failure.
- For confidential facilities, select devices whose cloud connection can be disabled and define access levels (full, viewer, service).
Who should read it
Mechanical engineers and commissioning teams designing data center chilled water hydraulics, balancing and pressure maintenance.
Document contents
- Introduction
- The unique HVAC demands of data centres
- 1. Precision cooling (balancing valves, differential pressure controllers, TA-Modulator, liquid cooling)
- 2. High energy efficiency (TA-Smart)
- 3. No margin for error (pressure maintenance, air and dirt removal, power outage protection)
- 4. Enhancing safety and data protection
- 5. Design complexity (new build, modular prefabricated, renovation)
- Reference cases
- HVAC applications (Uptime Institute Tier I, II schematics)
Publication details
- Authors
- IMI Hydronic Engineering
- Publisher
- IMI Hydronic Engineering
- Year
- 2024
- Document number
- ENG-02/2024
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Official public manufacturer source inspected. No redistribution permission established. Metadata and original brief summaries only; local files are research evidence, not a redistribution package.
Citation
IMI Hydronic Engineering (2024). HVAC Solutions for Data Centres. IMI Hydronic Engineering. ENG-02/2024. https://assets.imi-hydronic.com/Complementary%20documents/Italy/HVAC_solutions_Data%20Centres.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.