Technical guideFree to read2026

Renewable Power Generation Costs in 2025: Executive Summary

Original title Renewable power generation costs in 2025: Executive summary

International Renewable Energy Agency · Saied Dardour, Deborah Ayres et al.

IRENA summary (July 2026): in 2025 solar PV LCOE was USD 44, onshore wind USD 33 and offshore wind USD 78/MWh, and over 90% of new utility-scale renewable capacity was cheaper than the cheapest new fossil option.

On this page

Overview

The executive summary of the International Renewable Energy Agency's (IRENA) annual cost report says renewable generation costs began to stabilise in 2025 after more than a decade of steep declines. The global weighted-average LCOE stayed at the 2024 level of USD 44/MWh for solar PV, fell to USD 33/MWh for onshore wind and USD 78/MWh for offshore wind. Most dispatchable renewables became costlier: hydropower USD 62, geothermal USD 89, concentrated solar power (CSP) USD 115/MWh; bioenergy fell to USD 86/MWh. All values are in 2025 USD.

Since 2010 the cost of solar PV has fallen 89%, onshore wind 71% and offshore wind 63%. More than 90% of newly commissioned utility-scale renewable projects in 2025 delivered power cheaper than the cheapest new fossil option. New gas-fired generation became more expensive: a turbine shortage, partly linked to data-centre demand, roughly doubled the capital cost of a new combined-cycle plant to about USD 2,400/kW in the US and pushed LCOE towards USD 100/MWh in high-gas-price markets (Italy, Germany, Japan).

Storage and hybrid systems stand out: the installed cost of four-hour utility-scale batteries fell about 30% in 2025 to about USD 140/kWh (about 95% below 2010, and under USD 70/kWh in China). The firm LCOE of solar-plus-battery systems at 95% reliability fell from above USD 100/MWh in 2020 to below USD 85/MWh in 2025 at high-quality sites. About a quarter of newly commissioned utility-scale solar in 2025 was paired with batteries. The executive summary gives headline findings only; country and technology detail sits in the full report.

Financing cost is a major factor: national macroeconomic conditions explain about 2.3 times as much variation in financing cost as technology. In 2025, more than 690 GW of new renewable capacity was added (solar above 500 GW, wind about 160 GW) and renewables overtook coal in installed capacity. The report estimates renewables avoided about USD 480 billion in fossil fuel costs and about 8.4 Gt of CO2 emissions.

Key points

  1. 2025 global weighted-average LCOE: solar PV USD 44, onshore wind 33, offshore wind 78, hydropower 62, geothermal 89, CSP 115, bioenergy 86/MWh.
  2. Declines since 2010: solar PV 89%, onshore wind 71%, offshore wind 63%.
  3. More than 90% of utility-scale renewable capacity commissioned in 2025 was cheaper than the cheapest new fossil alternative.
  4. A turbine shortage doubled new combined-cycle capital cost to about USD 2,400/kW in the US; gas LCOE is about USD 100/MWh in high-gas-price markets and USD 50-60/MWh where gas is cheap.
  5. In China onshore wind is USD 27, offshore wind USD 49 and solar USD 36/MWh; US offshore wind is USD 141/MWh.
  6. Four-hour utility-scale battery cost fell about 30% in 2025 to about USD 140/kWh; under USD 70/kWh in China.
  7. Solar-plus-battery firm LCOE at 95% reliability fell from above USD 100/MWh in 2020 to below USD 85/MWh in 2025; further falls of about 30% by 2030 and 40% by 2035 are projected.
  8. About a quarter of new utility-scale solar in 2025 was paired with batteries.
  9. National macroeconomic conditions explain about 2.3 times as much variation in financing cost as technology.
  10. More than 690 GW of new renewable capacity was added in 2025 (solar above 500 GW, wind about 160 GW).

Using it in design

  • In data-centre energy cost scenarios, compare regional LCOE and financing conditions for renewable PPA pricing with this report's country values.
  • If 24/7 renewable supply is considered, evaluate the firm LCOE (solar plus battery, 95% reliability) together with the standalone LCOE.
  • For projects planning gas-based backup and baseload generation, treat turbine shortage and capital cost increases as budget and lead-time risks.
  • When deciding on on-site batteries, note that four-hour system costs (about USD 140/kWh global average) are falling fast while input price volatility remains.
  • Reflect country and financing risk, a bigger price component than technology choice, in PPA negotiations.

Who should read it

Investors, energy advisers and policy analysts setting data-centre energy procurement and sustainability strategy.

Document contents

  1. Highlights
  2. Executive summary
  3. Renewable capacity additions
  4. LCOE, total installed cost and capacity factor trends
  5. Cost advantage of renewables over fossil fuels
  6. Hybrid systems and storage

Publication details

Authors
Saied Dardour; Deborah Ayres; Lourdes Zamora
Publisher
International Renewable Energy Agency
Year
2026
Document number
ISBN 978-92-9260-749-4
Document language
English
Source type
Government / public
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

PDF p.2 explicitly permits use, sharing, copying, reproduction, printing and storage with acknowledgement to IRENA, subject to separate third-party rights. HTML landing still returns 403; official PDF was opened. Round 3/4 ingestion retains bibliographic metadata only; no local full text is redistributed.

Citation

Saied Dardour; Deborah Ayres; Lourdes Zamora (2026). Renewable power generation costs in 2025: Executive summary. International Renewable Energy Agency. ISBN 978-92-9260-749-4. https://www.irena.org/-/media/Files/IRENA/Agency/Publication/2026/Jul/IRENA_TEC_RPGC_2025_Executive_summary_2026.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cost studies in SoSo CAD

Calculate equipment cost, energy cost and total cost of ownership (TCO) from the design’s quantities and your own price assumptions.

CAPEX and TCO estimates in the SoSo CAD cost workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.