24/7 Renewables: The Economics of Firm Solar and Wind
Original title 24/7 renewables: The economics of firm solar and wind
International Renewable Energy Agency (IRENA) · Saied Dardour, Deborah Ayres et al.
IRENA's May 2026 report measures the cost of round-the-clock solar, wind and battery power with a firm LCOE: about USD 54-82/MWh in favourable regions in 2025, falling below USD 50/MWh by 2035.
On this page
Overview
The International Renewable Energy Agency (IRENA) report examines, at asset level, the cost of turning variable solar and wind output into a flat, continuous supply, known as firming. It introduces the firm LCOE (F-LCOE): the standalone LCOE plus a firming premium for storage, generation overbuild and complementary renewables. The default reliability target is 95%, a simplified energy-based measure of how much annual demand the project can meet, which differs from power system reliability.
The report notes that between 2010 and 2024 installed costs fell 87% for solar PV (USD 708/kW), 55% for onshore wind (USD 1,066/kW) and 93% for battery storage (from USD 2,634 to USD 197/kWh). Firm LCOE for solar-plus-battery configurations fell from above USD 100/MWh in 2020 to about USD 54-82/MWh in 2025 in favourable regions. Under current assumptions a further drop of roughly 30% by 2030 and 40% by 2035 is projected.
China sets the global cost floor: most of 252 utility-scale solar projects commissioned in 2024 can deliver firm electricity below USD 100/MWh, with minimum values of USD 30/MWh at 90% reliability and about USD 46/MWh at 99%. The UAE's Al Dhafra complex will combine 5.2 GW of solar with 19 GWh of batteries to deliver a firm 1 GW at about USD 70/MWh. The report names data centres and AI workloads among users needing uninterrupted, high-quality power.
The report carries two caveats: it does not advocate firm, continuous supply as a universal objective, and the flat output profile is a modelling assumption, not an operating prescription. F-LCOE should be read as a conservative project-level upper bound for grid-constrained or islanded cases, since system-level integration usually delivers comparable reliability more cheaply. It also discusses the move from annual matching to hourly and location-matched accounting.
Key points
- F-LCOE is the standard LCOE plus a firming premium (storage, overbuild, complementary sources); the default reliability target is 95%.
- Installed cost declines 2010-2024: solar PV 87% (USD 708/kW), onshore wind 55% (USD 1,066/kW), batteries 93% (USD 197/kWh).
- Solar-plus-battery firm LCOE was above USD 100/MWh in 2020 and is about USD 54-82/MWh in favourable regions in 2025.
- Declines of about 30% by 2030 and about 40% by 2035 are projected, taking the best sites below USD 50/MWh.
- In China most of 252 solar projects can deliver firm electricity below USD 100/MWh; the minimum is USD 30/MWh at 90% reliability and USD 46/MWh at 99%.
- At high-quality sites in Brazil, India, Australia and South Africa, 2025 firm LCOE is about USD 65-82/MWh against unfirmed LCOE of USD 29-39/MWh.
- In the US, financing costs, interconnection charges and permitting complexity keep firm costs above other regions.
- Al Dhafra: 5.2 GW of solar and 19 GWh of batteries for a firm 1 GW, estimated at about USD 70/MWh.
- Batteries are modelled as four-hour lithium-ion systems; the flat output profile is a proxy for continuous consumers such as data centres.
Using it in design
- When evaluating 24/7 renewable supply for a data centre, compare the firm LCOE of a solar, wind and battery hybrid portfolio at the regional resource quality against this report's ranges.
- When choosing an hourly matching target (for example 90%, 95%, 99%), assess how cost rises with the reliability target using China's move from USD 30 to USD 46/MWh.
- On grid-constrained sites, examine co-locating solar, wind and battery at one connection point as a way to use connection capacity more efficiently.
- Use the figures as an upper-bound benchmark rather than a project quote; real cost depends on site resource, financing and connection charges.
- Frame corporate clean-energy commitments around possible hourly and location-based matching rather than annual matching.
Who should read it
Investors, energy procurement teams and policy analysts setting data-centre power supply and sustainability strategy.
Document contents
- Executive summary
- 1. The rise of round-the-clock renewable power (beyond LCOE: why a system perspective matters; from system models to project-level benchmarks)
- 2. The economics of firm renewable power (firm LCOE, comparison across markets, competitiveness with fossil fuels, cost drivers)
- 3. From cost competitiveness to deployment at scale (technology learning, matching technology to context, the role of policy)
- Annexes: firm LCOE methodology, capital and operating expenditure, project timeline and financing assumptions
Publication details
- Authors
- Saied Dardour; Deborah Ayres; Lourdes Zamora
- Publisher
- International Renewable Energy Agency (IRENA)
- Year
- 2026
- Document number
- ISBN 978-92-9260-736-4
- Document language
- English
- Source type
- Industry body
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Official PDF opened via web and copyright page 2 inspected: IRENA permits reuse/copying with acknowledgement, except separately attributed third-party material. Publisher HTML landing https://www.irena.org/Publications/2026/May/24-7-renewables-The-economics-of-firm-solar-and-wind was opened/attempted but returned 403 in web and TinyFish; licence evidence is the actual publication, not successful HTML access. Round 2 ingestion retains bibliographic metadata only; no local full text is redistributed.
Citation
Saied Dardour; Deborah Ayres; Lourdes Zamora (2026). 24/7 renewables: The economics of firm solar and wind. International Renewable Energy Agency (IRENA). ISBN 978-92-9260-736-4. https://www.irena.org/-/media/Files/IRENA/Agency/Publication/2026/May/IRENA_TEC_24-7_renewables_2026.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.