CE and ErP: Ecodesign Requirements and Energy Labels (ISKİD presentation, April 2021)
Original title İSKİD Perspektifinden CE ve ErP Yönetmelikleri
İSKİD · Andaç Yakut
An April 2021 presentation prepared for ISKİD: the EU Ecodesign (ErP) framework, LOT 10, LOT 1/2 and EU 2016/2281 (LOT 21) rules for air conditioners, rooftops and chillers above 12 kW, with Turkish regulation.
On this page
Overview
The presentation starts from EU environmental policy: the 2030 commitment to cut greenhouse gases by 40 percent, later raised to 55 percent under the EU Green Deal, and the goal of the first climate-neutral continent by 2050. The ErP (energy-related products) directive is divided into product groups (LOTs) in that framework, and products that do not meet minimum efficiency requirements cannot carry the CE mark or be placed on the market.
For LOT 10 (air conditioners below 12 kW), seasonal efficiency (SEER, SCOP) replaces nominal efficiency. Seasonal efficiency weighs power drawn in annual cooling by part-load ratio and outdoor dry bulb temperature, so it represents real operation better. Example thresholds: for units below 6 kW, SEER 3.6/SCOP 3.4 in 2014 and SEER 4.6/SCOP 3.8 in 2015, plus indoor and outdoor sound power limits.
LOT 1 covers water-based space heaters: ecodesign applies up to 400 kW and energy labelling up to 70 kW. Seasonal space heating efficiency is ηs = SCOP/CC - F(i), with a primary energy factor of 2.5, 3 percent control correction and 5 percent auxiliary pump correction. Nitrogen oxide limits are 56 mg/kWh for gas boilers and 120 mg/kWh for liquid fuel (26 September 2019).
Air conditioners above 12 kW, VRF, rooftops, comfort chillers, high temperature process chillers and fan coil units fall under EU 2016/2281 (LOT 21), in force in the EU since 1 January 2018. The last section lists current Turkish regulations: the fan regulation (ENER LOT 11, in force 20 December 2020), the process chiller and condensing unit regulation (ENTR LOT 1, 5 September 2021) and the framework energy labelling regulation (2 March 2021).
Key points
- EU Green Deal: climate neutral by 2050 and at least 55 percent emission cut by 2030.
- Products that do not meet ecodesign requirements cannot carry the CE mark or be placed on the market.
- LOT 10 (air conditioners below 12 kW): seasonal efficiency (SEER/SCOP) instead of nominal; minimum SEER 4.6 and SCOP 3.8 for units below 6 kW in 2015.
- LOT 1: ecodesign up to 400 kW, energy label up to 70 kW; primary energy factor 2.5 in the ηs formula.
- NOx limits: 56 mg/kWh for gas-fired boilers, 120 mg/kWh for liquid fuel.
- EU 2016/2281 (LOT 21): air conditioners above 12 kW, VRF, rooftop, comfort chillers, high temperature process chillers and fan coils, in force in the EU since 1 January 2018.
- Turkey: the fan regulation (LOT 11) took effect 20 December 2020; the process chiller and condensing unit regulation (ENTR LOT 1) was due 5 September 2021.
- The framework Energy Labelling Regulation was published in the Official Gazette on 2 March 2021.
Using it in design
- When selecting air conditioners, chillers and rooftops above 12 kW, verify from the product sheet and technical file that the unit meets the EU 2016/2281 (LOT 21) seasonal efficiency requirements.
- In the specification, state whether a chosen data centre unit falls within the seasonal efficiency scope (comfort versus high temperature process chiller).
- For capacity comparisons, request seasonal efficiency data and part-load behaviour, not only nominal values.
- Check that ENER LOT 11 requirements (125 W-500 kW) apply to the fans chosen for air handling and fan walls.
- Require the CE mark and ecodesign product information (product fiche, technical file) in the handover documents.
Who should read it
Engineers selecting air conditioning and cooling equipment, manufacturers' compliance staff and specification writers.
Document contents
- EU environmental policies
- What is ErP
- Ecodesign and energy labels for air conditioners (LOT 10)
- Ecodesign and energy labels for heating devices (LOT 1 and 2)
- Ecodesign for air conditioners, rooftops and chillers above 12 kW (LOT 21)
- Current developments in Turkey
Publication details
- Authors
- Andaç Yakut
- Publisher
- İSKİD
- Year
- 2021
- Document number
- CE ve ErP semineri sunumu, Nisan 2021
- Document language
- Turkish
- Source type
- Expert / community
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Yayıncının açık PDF dosyası okundu. Açık erişim yeniden dağıtım izni anlamına gelmez; yalnızca künye, özgün kısa özet ve sayfa atıfları kaydedildi. PDF s. 2 tüm hakların saklı olduğunu belirtir. 2021 tarihli mevzuat anlatımıdır; güncel yükümlülük doğrulaması yapılmadı.
Citation
Andaç Yakut (2021). İSKİD Perspektifinden CE ve ErP Yönetmelikleri. İSKİD. CE ve ErP semineri sunumu, Nisan 2021. https://iskid.org.tr/wp-content/uploads/2021/04/ISKID-ERP-SUNUM-NISAN-2021_AndacYAKUT.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.