Information technology - Data centres - Key performance indicators - Part 4: IT Equipment Energy Efficiency for servers (ITEEsv)
ISO/IEC · ISO/IEC JTC 1
The standard defining the ITEEsv indicator for the energy efficiency characteristics of a data centre's server fleet; it addresses IT equipment efficiency, not facility overhead.
This document is sold by ISO/IEC and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.
On this page
Overview
ISO/IEC 30134-4:2017 is the fourth part of the key performance indicator (KPI) series for data centres and defines IT Equipment Energy Efficiency for servers, ITEEsv. The indicator quantifies the energy efficiency characteristics of the servers in a data centre. The first edition was published on 18 October 2017 and runs to 12 pages. This page rests on the publisher's public abstract and product metadata, not on the full text of the standard.
According to the publisher's abstract, ITEEsv can be calculated using pre-existing or context-specific server performance benchmarks. The standard defines the indicator's purpose, how to use it and how to report it. Its goal is to help raise the aggregate energy effectiveness of the server fleet. In other words, the indicator is meant to track the combined efficiency of all servers in the facility, not that of a single machine.
ITEEsv measures something different from PUE, which captures the overhead of the facility infrastructure: it measures the energy efficiency of the IT equipment itself. The two indicators complement each other and do not replace one another. The standard is related to ISO/IEC 30134-5, ISO/IEC 21836 and EN 50600-4-7.
Key points
- ITEEsv is a KPI quantifying the energy efficiency characteristics of servers in a data centre.
- It may be calculated using pre-existing or context-specific server performance benchmarks.
- The standard defines the indicator's purpose, use and reporting.
- The aim is to help raise aggregate server energy effectiveness.
- Edition 1, published 18 October 2017, 12 pages.
- Unlike PUE, it measures IT efficiency, not facility overhead.
- Related standards: ISO/IEC 30134-5, ISO/IEC 21836, EN 50600-4-7.
Using it in design
- Collect server performance scores and power at maximum performance for the hall’s fleet ITEEsv calculation.
- Keep it separate from PUE: one measures IT efficiency, the other facility overhead; show them separately in reports.
- In server procurement and refresh decisions, use it to compare models that deliver similar performance at lower power.
- State the benchmark source and method used in the calculation in the report.
Who should read it
Operators tracking data center energy efficiency, teams planning server procurement and capacity, and engineers preparing KPI reports.
Related standards
- ISO/IEC 30134-5
- ISO/IEC 21836
- EN 50600-4-7
Publication details
- Authors
- ISO/IEC JTC 1
- Publisher
- ISO/IEC
- Year
- 2017
- Document number
- ISO/IEC 30134-4:2017
- Document language
- English
- Source type
- Standard
- Access
- Paid; available from the publisher
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.
Citation
ISO/IEC JTC 1 (2017). Information technology - Data centres - Key performance indicators - Part 4: IT Equipment Energy Efficiency for servers (ITEEsv). ISO/IEC. ISO/IEC 30134-4:2017. https://webstore.iec.ch/en/publication/61810
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.