Information technology - Data centres - Key performance indicators - Part 5: IT Equipment Utilization for servers (ITEUsv)
ISO/IEC · ISO/IEC JTC 1
ISO/IEC standard defining ITEUsv, a KPI for how well servers in a data centre are utilised.
This document is sold by ISO/IEC and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.
On this page
Overview
ISO/IEC 30134-5 is the fifth part of the data centre key performance indicator (KPI) series and defines ITEUsv, a measure of server utilisation. Its purpose is to drive aggregate server energy efficiency, since an idle server keeps drawing power much as a loaded one does. Edition 1 was published on 26 October 2017 and runs to seven pages.
The method's defining feature is that it uses only server CPU utilisation. There is also a clear boundary: servers whose computation is mainly delivered by auxiliary processing accelerators (APAs) are out of scope. In GPU- or accelerator-heavy AI halls the indicator therefore gives no meaningful result and could mislead. The standard covers purpose, conceptual definition, use and reporting.
The document sits alongside ISO/IEC 30134-4 and EN 50600-4-8 as a complementary measure. The record gives no threshold or target values, so ITEUsv should be treated as a monitoring and benchmarking tool, not a compliance condition. Its limitation is that it is CPU-only and does not reflect memory, network or storage utilisation.
Key points
- ITEUsv is specified as a KPI for utilisation of servers in a data centre.
- The indicator uses only server CPU utilisation.
- Servers where most computation comes from auxiliary processing accelerators are out of scope.
- The standard covers purpose, conceptual definition, use and reporting.
- Edition 1 published 26 October 2017, seven pages.
- Related standards: ISO/IEC 30134-4 and EN 50600-4-8.
Using it in design
- In the operations dashboard, compute ITEUsv only for CPU-centric servers.
- Flag GPU and accelerator racks as out of scope so AI halls are not given a misleading utilisation figure.
- Use utilisation data to derive realistic IT load profiles for cooling and UPS sizing.
Who should read it
Operations engineers and energy-efficiency leads who report data centre KPIs.
Related standards
- ISO/IEC 30134-4
- EN 50600-4-8
Publication details
- Authors
- ISO/IEC JTC 1
- Publisher
- ISO/IEC
- Year
- 2017
- Document number
- ISO/IEC 30134-5:2017
- Document language
- English
- Source type
- Standard
- Access
- Paid; available from the publisher
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.
Citation
ISO/IEC JTC 1 (2017). Information technology - Data centres - Key performance indicators - Part 5: IT Equipment Utilization for servers (ITEUsv). ISO/IEC. ISO/IEC 30134-5:2017. https://webstore.iec.ch/en/publication/61861
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.