StandardPaid2023

Guidelines and Experimental Hydraulic Performance Evaluation for Single-Phase CDUs Under Steady and Transient Events (ITherm 2023)

IEEE · Ali Heydari

A metadata-only record of an ITherm 2023 study that tested liquid-to-air and liquid-to-liquid coolant distribution units on multi-rack setups, aiming to produce commissioning rules for CDUs.

This document is sold by IEEE and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.

On this page

Overview

This study by Ali Heydari for IEEE ITherm 2023 (22nd Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems) tests liquid-to-air and liquid-to-liquid coolant distribution units (CDUs) on multi-rack setups loaded with thermal test vehicles (TTVs). The record rests only on the abstract; the full text was not read. As motivation, it points to the inefficiency of raised-floor air delivery at high density, and the abstract cites cooling as about 40% of data-centre energy use.

The method has two parts. The first is measuring hydro-thermal performance under different secondary-coolant conditions. The second is examining transient behaviour: TTV cooling loops were disconnected and reconnected in different sequences to observe system response. Both liquid-to-air and liquid-to-liquid CDUs were evaluated on multiple racks with varying numbers of thermal test vehicles. This experimental set-up aims to show how a CDU responds to sudden changes in flow and pressure.

The stated outcome of the study is a set of rules and guidelines for commissioning single-phase CDUs. As a limit, this is only an abstract-level record; measurement results, pressures and flow values are not included. Even so, it conveys the message that transient events, meaning loop disconnection and reconnection, should be an integral part of commissioning tests.

Key points

  1. Both liquid-to-air and liquid-to-liquid CDUs were evaluated on multiple racks with varying numbers of thermal test vehicles.
  2. Transient events were created by disconnecting and reconnecting TTV loops in different sequences to observe system response.
  3. The study aims to establish rules and guidelines for commissioning single-phase CDUs.
  4. The abstract cites cooling as about 40% of data-centre energy use as motivation.
  5. Hydro-thermal performance was measured under different secondary-coolant conditions.

Using it in design

  • Include loop connect/disconnect transient tests in commissioning scripts generated for liquid-cooled rows.
  • Record CDU response (flow, differential pressure) as acceptance criteria.
  • Include different disconnection and reconnection sequences in the commissioning test plan.

Who should read it

Engineers responsible for commissioning liquid-cooled rows and CDU manufacturers.

Related standards

  • ASHRAE Liquid Cooling Guidelines

Publication details

Authors
Ali Heydari
Publisher
IEEE
Year
2023
Document number
DOI 10.1109/ITherm55368.2023.10177633
Event
IEEE ITherm 2023 (22nd Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems)
Document language
English
Source type
Standard
Access
Paid; available from the publisher
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document

Citation

Ali Heydari (2023). Guidelines and Experimental Hydraulic Performance Evaluation for Single-Phase CDUs Under Steady and Transient Events (ITherm 2023). IEEE. DOI 10.1109/ITherm55368.2023.10177633. IEEE ITherm 2023 (22nd Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems). https://par.nsf.gov/biblio/10435660

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.