Package Cooling Towers, Evaporative Condensers and Closed Circuit Fluid Coolers (IWC Industrial)
Original title Package Cooling Towers: January 2026
IWC
IWC Industrial's January 2026 catalogue presents EWK package cooling towers (up to 350 m³ of water per hour per tower), FM towers and closed circuit coolers also used for data centre cooling.
On this page
Overview
The catalogue presents factory-built package cooling towers, evaporative condensers and closed circuit fluid coolers from IWC Industrial, a subsidiary of NEXT Cooling. The small EWK towers are plug and play units for small and medium applications such as distilleries, dry cleaners and wineries; the multi-fan FM range is a high-capacity range for larger process facilities and remote locations.
EWK towers have a glass reinforced polyester casing and can recool up to 350 m³ of water per hour in a single tower. Models run from EWK036 to EWK1262 with motors from 0.37 to 15 kW. Components are the casing, fill (PVC or polypropylene), drift eliminator, self-cleaning full-cone plastic nozzles, inlet louvres, basket strainer, float-valve makeup and the mechanicals (motor, fan, fan guard, motor support).
The FM range has an internal frame of 3CR12 or stainless steel (304 or 316) and fibre reinforced polyester cladding. The closed circuit cooler and evaporative condenser models are FM100, FM135, FM160 and FM205, with motors of 5.5 or 7.5 kW and operating weights of 3,500 to 5,850 kg. In a closed circuit unit the process fluid flows through serpentine coil tubes without touching the spray water, preventing fouling, and the units need significantly less space and power than dry coolers. They can run in dry mode at low load or low dry-bulb conditions to save water.
Computer room and data centre cooling is listed among the applications. The catalogue is a general product introduction and carries no approach temperature or capacity curves.
Key points
- EWK range: EWK036 to EWK1262; up to 350 m³ of water per hour recooled in a single tower.
- EWK motors 0.37 to 15 kW; glass reinforced polyester casing.
- FM range is multi-fan with 3CR12 or stainless steel (304/316) frame and FRP cladding.
- Closed circuit cooler and evaporative condenser models: FM100, FM135, FM160, FM205.
- FM motors 5.5 or 7.5 kW; operating weight 3,500 to 5,850 kg.
- In closed circuit units the process fluid does not touch the spray water, lowering fouling risk.
- Closed circuit coolers need significantly less space and power than dry coolers.
- Dry mode at low load or low dry-bulb conditions saves water.
- Applications include computer room and data centre cooling.
Using it in design
- When selecting a closed circuit cooler for a data centre, estimate water use by calculating dry-mode hours from the annual dry-bulb distribution.
- Compare the space and power advantage of the closed circuit option with a dry cooler alternative on footprint and electrical demand.
- Add unit operating weights (130-9,200 kg for EWK, 3,500-5,850 kg for FM) to the roof structural calculation.
- Choose materials (coil: galvanized carbon steel, 304 or 316 stainless) according to water quality.
- Because the catalogue gives no capacity or approach temperature, have the manufacturer select at the design wet-bulb conditions.
Who should read it
Mechanical designers and procurement engineers selecting cooling towers and closed circuit coolers.
Document contents
- Components
- EWK range
- FM range
- Closed circuit fluid coolers and evaporative condensers
- Evaporative condenser and closed circuit cooling towers
- Other services
Publication details
- Authors
- IWC
- Publisher
- IWC
- Year
- 2026
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
IWC (2026). Package Cooling Towers: January 2026. IWC. https://iwc.co.za/wp-content/uploads/2026/02/IWC_PCT_SA_Jan2026_SA_FA-digital.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.