Technical guideFree to read2022

KKT chillers Products Catalog (US): Nano, Vario and Compact Line Process Chillers

Original title KKT chillers US product catalogue 07/29/2022, Compact Line pp.14–15

KKT chillers

KKT chillers' 2022 US catalog: Nano (1.9-7.0 kW), Vario (6.2-28.5 kW) and Compact (34-204 kW) process chiller lines with R410A/R134a, -25 to 50 °C ambient range and technical data tables.

On this page

Overview

The catalog presents the industrial process cooling products of KKT chillers, a brand of ait-deutschland GmbH. Series devices cover 1 to 500 kW cooling capacity, with customised solutions on top. The Technology Center in Kasendorf, Germany tests products to current standards with 32 test stations and climatic chambers, and the Wood Dale team in the US supports more than 4,000 installed chillers.

The portfolio has four main lines: Nano Line (nBoxX, 1.9-7.0 kW), Vario Line (vBoxX, 6.2-28.5 kW), Compact Line (34-204 kW) and customer-specific OEM solutions. Heat exchangers and accessories (1-1,000 kW transmission power) are a separate group. Target fields include laser, machine tools, plastics and packaging, welding, electronics, chemicals, medical imaging and filtration.

Technical tables give net cooling capacity, refrigerant (R410A, R134a), refrigerant charge, sound pressure level, ambient temperature range and weight. The Nano line has a 15-45 °C ambient range and sound below 62 dB(A). The Vario and Compact lines show -25 to 50 °C ambient and 54-69 dB(A). Speed-controlled compressors and EC fans give temperature constancy of ±0.5 K.

The Compact Line is presented as up to 21 percent more efficient than the Ecodesign regulation requires. The catalog is for process cooling; it gives no data hall capacity, redundancy or wet/dry bulb conditions. In a data centre it serves as candidate product information for auxiliary process circuits or laboratory cooling.

Key points

  1. Series chillers span 1-500 kW; catalog lines are Nano 1.9-7.0 kW, Vario 6.2-28.5 kW and Compact 34-204 kW.
  2. The Nano line has an ambient range of 15-45 °C and sound level below 62 dB(A).
  3. The Vario and Compact lines have an ambient range of -25 to 50 °C; sound pressure levels range from 54 to 69 dB(A).
  4. Refrigerants are R410A and R134a; Compact line charge is in the 6-23.5 kg range.
  5. Speed-controlled compressors and EC fans give temperature constancy of ±0.5 K.
  6. The Compact Line is up to 21 percent more efficient than the Ecodesign regulation requires.
  7. More than 4,000 KKT chillers are installed in the US; the Kasendorf Technology Center has 32 test stations and 6 climatic chambers.
  8. Coolant options listed include DI water, water, glycol and oil.

Using it in design

  • For auxiliary process circuits in a data centre (laboratory, metrology, small technical cooling), match required capacity to the Nano, Vario or Compact range.
  • Choose the line by comparing its ambient range (-25/50 °C or 15-45 °C) with site extremes.
  • Check the sound pressure level (54-69 dB(A)) against environmental and building limits.
  • Add the R410A/R134a charge and applicable F-gas or refrigerant regulation to the project checklist.
  • Before sizing for data hall heat load, ask the manufacturer for full capacity tables and an N+1 recommendation; the catalog targets process cooling.

Who should read it

Mechanical engineers and buyers looking for packaged chillers for process or auxiliary cooling in data centre facilities.

Document contents

  1. Vision
  2. Locations (US and Kasendorf)
  3. Product portfolio and applications
  4. Nano Line
  5. Vario Line
  6. Compact Line
  7. Heat exchangers and accessories
  8. OEM solutions

Publication details

Authors
KKT chillers
Publisher
KKT chillers
Year
2022
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

KKT chillers (2022). KKT chillers US product catalogue 07/29/2022, Compact Line pp.14–15. KKT chillers. https://www.kkt-chillersusa.com/wp-content/uploads/2022/08/KKT-chillers-Catalog-US-Version_072922.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.