Kuken CT-9 Cooling Tower General Catalog, December 2024
Original title Kuken Cooling Tower Catalogue CT-9-2412
Kuken
Kuken Kogyo's Japanese-language CT-9 catalog (December 2024) presents open and closed cooling towers with low-noise and plume-abatement series, an underblow pipe cutting blowdown time by about 40%, and freeze protection options.
On this page
Overview
The document is the CT-9 general cooling tower catalog issued at the end of 2024 by the Japanese manufacturer Kuken Kogyo (Kuken), written in Japanese. A cooling tower is described as an auxiliary of the chiller, a machine that cools water using the latent heat of evaporation. The catalog offers open (water in direct contact with air) and closed (indirect contact) towers in standard, low-noise (R), ultra-low-noise (S), energy-saving ultra-low-noise (N, open type only), extremely-low-noise (E, standard only) and plume-abatement (M) series.
The selection section explains the model code: open or closed, single or double inlet, series, capacity, chiller type (inlet water 37 °C for centrifugal, 37.5 °C for absorption), noise class and plume preference. The method is to pick the column matching inlet and outlet water temperature and outdoor wet-bulb, then the row exceeding the required water flow. In the example, an absorption chiller with 37.5/32 °C water, 27 °C wet-bulb and 11.0 m³/h flow selects SKCL-11 GRo.
It also introduces the underblow pipe, which discharges concentrated water first; in an SKBL-225R test (ΔTw 5 °C, 102 m³/h, 8 hours) the blowdown time needed to cut conductivity by 25% falls from about 6.0 hours to 3.5 hours (about 40% shorter). Other products are large-capacity open towers, a heating tower system, radiators, the Ultra Fan direct-drive fan and the HFD flat-belt system. The technical data section covers freeze protection, vibration isolation, water quality, maintenance and installation cautions.
The document is a general HVAC and industrial cooling tower product catalog, not a data-center-specific design guide, but its tower selection method, noise classes and water-saving features serve as a reference for cooling water plant design.
Key points
- Open (direct contact) and closed (indirect contact) towers; in closed models the circulating water stays enclosed, which eases water quality management.
- Noise classes: R (low), S (ultra-low), N (energy-saving ultra-low, open type only), E (extremely low, standard only); M is the plume-abatement series.
- Selection needs inlet and outlet water temperature and outdoor wet-bulb; tables assume 37 °C inlet water for centrifugal chillers and 37.5 °C for absorption chillers.
- Selection example: 37.5/32 °C water, 27 °C wet-bulb, 11.0 m³/h gives SKCL-11 GRo.
- The underblow pipe shortens blowdown time by about 40% (6.0 to 3.5 hours, SKBL-225R, ΔTw 5 °C, 102 m³/h) and reduces make-up water.
- Plume abatement mixes dry and wet fill sections; M7, M4 and M2 types exist, with no moving or controlled parts.
- Shipping forms: one-piece, two- or three-section, or split into parts; the part-split form suits elevator delivery.
- Options include freeze protection parts (plug heaters, basin heaters), vibration isolation, tower-integrated chemical dosing and a water quality guideline.
- Since 2022 a LEED-compatible drift eliminator option is offered.
Using it in design
- When selecting a cooling tower, set tower inlet temperature by chiller type (37 or 37.5 °C), design wet-bulb and flow, and confirm capacity against the manufacturer's tables.
- Where siting limits apply (neighbours, noise limits), check the noise class (R, S, N, E) against dB(A) values after capacity selection.
- For water-saving targets, include the underblow pipe and blowdown management options in make-up water (WUE) calculation.
- A closed tower can reduce the need for an intermediate heat exchanger on critical circuits that must avoid circulating-water fouling; compare efficiency and approach.
- In cold climates evaluate freeze protection heaters and drain arrangements; on dense sites evaluate the plume-abatement series.
Who should read it
Mechanical engineers and procurement teams selecting cooling towers and designing water-cooled chiller plants.
Document contents
- Kuken cooling towers and the role of a cooling tower
- Model selection by application and conditions
- Water saving with the underblow pipe
- Open cooling towers (standard, low-noise, ultra-low-noise, plume abatement)
- Closed cooling towers
- Other products (large-capacity open tower, heating tower, radiator, Ultra Fan, HFD system)
- Technical data (parts specifications, noise standard, options, freeze protection, vibration isolation, chemical dosing, water quality, maintenance, design, transport, installation and maintenance cautions)
Publication details
- Authors
- Kuken
- Publisher
- Kuken
- Year
- 2024
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Kuken (2024). Kuken Cooling Tower Catalogue CT-9-2412. Kuken. https://www.kuken.com/wp-content/uploads/2024/12/CT-9-2412.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.