Veri Merkezlerinde Enerji Devrimi: Soğutmanın Geleceği Şimdi Yazılıyor (Energy revolution in data centres, Lande)
Original title Veri Merkezlerinde Enerji Devrimi: Soğutmanın Geleceği Şimdi Yazılıyor
Lande Rack Cabinet · Pınar Kabil
The Lande Rack Cabinet article summarises cooling taking 40-50% of data-centre energy, PUE benchmarks, liquid cooling, waste-heat recovery and water footprint with cited figures.
On this page
Overview
The article is a cabinet manufacturer's blog post giving an introductory overview of energy, cooling and sustainability in data centres. It starts from the claim that about 40-50% of total data-centre energy goes to cooling, that data centres used about 3% of world electricity in 2025 and that consumption is forecast to double by 2030. For PUE it gives a world average of 1.56-1.57, an efficient-facility target of 1.2-1.3 and leaders at 1.03-1.10; Google's 2024 fleet average is 1.09.
Cooling technologies are covered as air cooling (hot-cold aisle), free cooling (a claim of up to 90% energy saving and 70% lower cost in cold climates), adiabatic cooling and liquid cooling. Liquids are said to transfer heat about 1000 times more effectively than air, with AI workloads at 50-140 kW rack densities and chips above 1200 W each. Direct-to-chip (cold plate) handles heat flux above 300 W/cm²; two-phase immersion 1500 W/cm² and above. Full liquid cooling is said to cut PUE from 1.4-1.6 to 1.03-1.2 and water use by 80% with closed loops.
The waste-heat section cites Meta Odense, Microsoft Helsinki/Espoo (225 million euro investment, about 40% of regional district heat), Stockholm Data Parks (100+ GWh a year), Google Hamina and Amazon Dublin. For Germany's Energy Efficiency Act (EnEfG) it gives from 1 July 2026 at least 10% ERF, PUE of 1.2 or less and 50% renewable energy, 15% ERF and 100% renewables in 2027, 20% ERF in 2028 and reporting for facilities of 300 kW IT capacity or more.
The Türkiye section covers geothermal potential (31,500 MWth technical potential, 170 fields) and use of waste heat in district heating, greenhouses and industry. The water footprint section reports a forecast that AI data-centre water use will rise about 11 times by 2028 and an expectation that rack density will rise from an average 36 kW in 2023 to 50 kW in 2027. The last section introduces the manufacturer's TROYA cabinet series. The article's market forecasts and savings claims should be read as context, not as engineering inputs.
Key points
- About 40-50% of total data-centre energy goes to cooling; data centres used about 3% of world electricity in 2025.
- PUE benchmarks: world average 1.56-1.57, efficient target 1.2-1.3, leaders 1.03-1.10; Google 2024 fleet average 1.09.
- Liquids transfer heat about 1000 times more effectively than air; AI workloads need 50-140 kW rack densities.
- Direct-to-chip handles heat flux above 300 W/cm²; two-phase immersion above 1500 W/cm².
- Full liquid cooling can cut PUE from 1.4-1.6 to 1.03-1.2 and water use by 80% with closed loops.
- Germany EnEfG: from 1 July 2026 at least 10% ERF, PUE 1.2 or less, 50% renewables; 15% ERF in 2027 and 20% ERF in 2028.
- The Microsoft Helsinki/Espoo waste-heat project is a 225 million euro investment covering about 40% of regional district heat.
- Stockholm Data Parks recovers 100+ GWh of heat a year from more than 20 suppliers.
- AI data-centre water use is forecast to rise about 11 times by 2028; rack density is expected at 36 kW in 2023 and 50 kW in 2027.
Using it in design
- Compare the design PUE target with the sector benchmarks (1.2-1.3 efficient, 1.03-1.10 leading) and compute free-cooling hours for the target climate.
- At rack densities above 50 kW assess the limit of air cooling; plan direct-to-chip cooling and a closed-loop water system early.
- To supply waste heat to district heating, investigate heat-pump lift to 60-75°C and neighbouring consumers (pools, greenhouses, campuses) at siting stage.
- For European projects add ERF, PUE and renewable-energy obligations (such as EnEfG) to the design brief.
- Include water use (WUE) and local water stress in siting and cooling topology decisions; do not use market forecasts as engineering inputs.
Who should read it
Data-centre managers and designers seeking an introductory view of cooling, waste heat and sustainability.
Document contents
- Why does it matter so much?
- PUE: the pulse of efficiency
- Cooling technologies: from past to future
- Liquid cooling: the star of the new era
- AI-based cooling optimisation
- Heat recovery: turning waste into opportunity
- Growing regulatory pressure in Europe
- Türkiye's geothermal advantage and transformation opportunity
- The hidden crisis: water footprint
- Lande and our sustainability vision
Publication details
- Authors
- Pınar Kabil
- Publisher
- Lande Rack Cabinet
- Year
- Year not stated
- Document language
- Turkish
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Üreticinin herkese açık kaynağı okundu. Açık erişim yeniden dağıtım izni değildir; tam metin kütüphaneye alınmaz. İmza PDF s. 16. Kesin yayın tarihi yoktur; metindeki 2025/2026 tahminleri yayın tarihi olarak alınmadı. Atıfsız sayısal performans/pazar iddiaları seçilen olgulara alınmadı.
Citation
Pınar Kabil Veri Merkezlerinde Enerji Devrimi: Soğutmanın Geleceği Şimdi Yazılıyor. Lande Rack Cabinet. https://www.lande.com.tr/uploads/catalog/blog-icerikleri/veri-merkezlerinde-enerji-tasarrufu-1.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.
