Liancheng SLG series stainless steel vertical multistage pump 50 Hz catalogue
Shanghai Liancheng
The Shanghai Liancheng SLG vertical multistage pump catalogue pairs flow and head in one table for 25 models; these are not duty points selected for a specific plant.
On this page
Overview
The Shanghai Liancheng (Group) catalogue gives the SLG series of stainless steel vertical multistage pumps for 50 Hz (2023 printing). Its sections are performance range, product range, product outline, running condition, model meaning, main purpose, motor, motor and pump noise, structure drawing, maximum working pressure, maximum environment temperature, minimum inlet pressure, performance curves, and performance and installation dimension tables.
For 25 models, flow and head are paired in the same table. These pairs are not presented as a duty point selected for a particular plant. Rated motor power is separate from measured electrical consumption at the selected flow, and material variants are not duplicated into separate model rows.
Key points
- SLG series stainless steel vertical multistage pump, 50 Hz catalogue.
- Flow and head are paired in one table for 25 models.
- The values are model comparison data, not selected duty points.
- Rated motor power is separate from measured consumption.
- Material variants are not duplicated into separate model rows.
Using it in design
- Select the pump by comparing the plant duty point (flow and head) with the curve in the table.
- Do not use rated motor power as measured electrical consumption.
- Check minimum inlet pressure and maximum working pressure in the system design.
Who should read it
Mechanical designers selecting vertical multistage pumps for cooling water and auxiliary circuits.
Publication details
- Authors
- Shanghai Liancheng
- Publisher
- Shanghai Liancheng
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Shanghai Liancheng Liancheng SLG series stainless steel vertical multistage pump 50 Hz catalogue. Shanghai Liancheng. https://www.lianchengpumps.com/uploads/38ee9e19.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.